B interferometry for the calibration of RF transmitter arrays
- 7 April 2009
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 61 (6) , 1480-1488
Abstract
Multiple‐channel RF transmission holds great promise for MRI, especially for human applications at high fields. For calibration it requires mapping the effective RF magnetic fields, B, of the transmitter array. This is challenging to do accurately and fast due to the large dynamic range of B and tight SAR constraints. In the present work, this problem is revisited and solved by a novel mapping approach relying on an interference principle. The B fields of individual transmitter elements are measured indirectly by observing their interference with a SAR‐efficient baseline RF field. In this fashion even small RF fields can be observed in the B ‐sensitive large‐flip‐angle regime. Based on a set of such experiments B maps of the individual transmitter channels are obtained by solving a linear inverse problem. Confounding relaxation and off‐resonance effects are addressed by an extended signal model and nonlinear fitting. Using the novel approach, 2D mapping of an 8‐channel transmitter array was accomplished in less than a minute. For validation it is demonstrated that mapping results do not vary with T1 or parameters of the mapping sequence. In RF shimming experiments it is shown that the measured B maps accurately reflect the linearity of RF superposition. Magn Reson Med, 2009.Keywords
This publication has 18 references indexed in Scilit:
- Actual flip‐angle imaging in the pulsed steady state: A method for rapid three‐dimensional mapping of the transmitted radiofrequency fieldMagnetic Resonance in Medicine, 2006
- Saturated double‐angle method for rapid B1+ mappingMagnetic Resonance in Medicine, 2006
- Frontiers of brain mapping using MRIJournal of Magnetic Resonance Imaging, 2006
- Transmit and receive transmission line arrays for 7 Tesla parallel imagingMagnetic Resonance in Medicine, 2005
- Parallel excitation with an array of transmit coilsMagnetic Resonance in Medicine, 2004
- Transmit SENSEMagnetic Resonance in Medicine, 2002
- 7T vs. 4T: RF power, homogeneity, and signal‐to‐noise comparison in head imagesMagnetic Resonance in Medicine, 2001
- Sensitivity and Power Deposition in a High-Field Imaging ExperimentJournal of Magnetic Resonance Imaging, 2000
- Imaging of the active B1 field in vivoMagnetic Resonance in Medicine, 1996
- Mapping of the Radiofrequency FieldJournal of Magnetic Resonance, Series A, 1993