Characterization of the New Serum Protein Reference Material ERM-DA470k/IFCC: Value Assignment by Immunoassay
Open Access
- 1 December 2010
- journal article
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 56 (12) , 1880-1888
Abstract
BACKGROUND: The availability of a suitable matrix reference material is essential for standardization of the immunoassays used to measure serum proteins. The earlier serum protein reference material ERM-DA470 (previously called CRM470), certified in 1993, has led to a high degree of harmonization of the measurement results. A new serum protein material has now been prepared and its suitability in term of homogeneity and stability has been verified; after characterization, the material has been certified as ERM-DA470k/IFCC. METHODS: We characterized the candidate reference material for 14 proteins by applying a protocol that is considered to be a reference measurement procedure, by use of optimized immunoassays. ERM-DA470 was used as a calibrant. RESULTS: For 12 proteins [α2 macroglobulin (A2M), α1 acid glycoprotein (orosomucoid, AAG), α1 antitrypsin (α1-protease inhibitor, AAT), albumin (ALB), complement 3c (C3c), complement 4 (C4), haptoglobin (HPT), IgA, IgG, IgM, transferrin (TRF), and transthyretin (TTR)], the results allowed assignment of certified values in ERM-DA470k/IFCC. For CRP, we observed a bias between the lyophilized and liquid frozen materials, and for CER, the distribution of values was too broad. Therefore, these 2 proteins were not certified in the ERM-DA470k/IFCC. Different value transfer procedures were tested (open and closed procedures) and found to provide equivalent results. CONCLUSIONS: A new serum protein reference material has been produced, and values have been successfully assigned for 12 proteins.Keywords
This publication has 13 references indexed in Scilit:
- Analysis of the Physicochemical State of C-Reactive Protein in Different Preparations Including 2 Certified Reference MaterialsClinical Chemistry, 2010
- Development and preparation of a new serum protein reference material: feasibility studies and processingClinical Chemistry and Laboratory Medicine (CCLM), 2010
- Determination of ceruloplasmin in human serum by SEC-ICPMSAnalytical and Bioanalytical Chemistry, 2006
- Commutability of Serum Protein Values: Persisting Bias among Manufacturers Using Values Assigned from the Certified Reference Material 470 (CRM 470) in the United StatesClinical Chemistry and Laboratory Medicine (CCLM), 2001
- Effect of Certified Reference Material 470 (CRM 470) on National Quality Assurance Programs for Serum Proteins in EuropeClinical Chemistry and Laboratory Medicine (CCLM), 2001
- Protein Standardization IV: Value Transfer. Procedure for the Assignment of Serum Protein Values from a Reference Preparation to a Target MaterialClinical Chemistry and Laboratory Medicine (CCLM), 2001
- Protein Standardization III: Method Optimization. Basic Principles for Quantitative Determination of Human Serum Proteins on Automated Instruments Based on Turbidimetry or NephelometryClinical Chemistry and Laboratory Medicine (CCLM), 2001
- Structure, oxidant activity, and cardiovascular mechanisms of human ceruloplasminLife Sciences, 1995
- Tables for An Approximate Test for Outliers in Linear ModelsTechnometrics, 1975
- Tables for An Approximate Test for Outliers in Linear ModelsTechnometrics, 1975