Intra- and inter-laboratory variability in human T-cell leukemia virus type-1 proviral load quantification using real-time polymerase chain reaction assays: A multi-center study
- 27 September 2010
- journal article
- research article
- Published by Wiley in Cancer Science
- Vol. 101 (11) , 2361-2367
Abstract
Human T-cell leukemia virus type-1 (HTLV-1) proviral load (VL) is an important determinant of viral pathogenesis and malignant evolution. Although VL has been quantified by in-house real-time quantifiable polymerase chain reaction (qPCR) technology, little is known about the harmonization among different VL assay systems. We evaluated intra- and inter-laboratory variability of VL measured at six laboratories using the same DNA samples seropositive for HTLV-1 in a two-step manner. The first study measured 60 samples by original in-house assays, finding that the median intra- and inter-laboratory coefficient of variation (CV) was 44.9% (range, 25.4-71.8%) and 59.9% (34.2-93.4%), respectively. The inter-laboratory correlation coefficients ranged from 0.760 to 0.875, indicating that VL were measured with good precision in each laboratory, but inter-laboratory regression slopes differed from 0.399 to 2.206, indicating that VL were measured with a wide variation between laboratories. To examine the effect of standardization of reference materials (RM) on the VL variability, we performed a second study using only 20 samples by substituting RM for plasmid including the HTLV-1 pX region. The median inter-laboratory CV for raw pX copy number was reduced significantly from 66.9% to 35.7%, whereas the median CV for the internal control remained almost unchanged, resulting in no improvement in inter-laboratory CV for VL. This indicates that each in-house assay system worked well with good precision, but standardizing RM alone was insufficient for harmonization. The relevant choice of not only RM, but also internal control genes for data normalization is expected to be realistic to standardize HTLV-1 VL measurement.Keywords
This publication has 19 references indexed in Scilit:
- Why the need for qPCR publication guidelines?—The case for MIQEMethods, 2010
- Multi-site assessment of the precision and reproducibility of multiple reaction monitoring–based measurements of proteins in plasmaNature Biotechnology, 2009
- Proviral Loads and Clonal Expansion of HTLV-1-Infected Cells following Vertical Transmission: A 10-Year Follow-Up of Children in JamaicaIntervirology, 2009
- The MIQE Guidelines: Minimum Information for Publication of Quantitative Real-Time PCR ExperimentsClinical Chemistry, 2009
- Interlaboratory Comparison of Epstein-Barr Virus Viral Load AssaysAmerican Journal of Transplantation, 2009
- Interlaboratory Comparison of Cytomegalovirus Viral Load AssaysAmerican Journal of Transplantation, 2009
- Quantifying HTLV‐I dynamicsImmunology & Cell Biology, 2007
- Discovery of HTLV-1, the first human retrovirus, its unique regulatory mechanisms, and insights into pathogenesisOncogene, 2005
- The Clonal Expansion of Human T Lymphotropic Virus Type 1–Infected T Cells: A Comparison between Seroconverters and Long‐Term CarriersThe Journal of Infectious Diseases, 2005
- Real-Time Polymerase Chain Reaction Assay for Cell-Associated HTLV Type I DNA Viral LoadAIDS Research and Human Retroviruses, 2000