Fecal Immunochemical Test Positivity Thresholds: An International Survey of Population-Based Screening Programs
Authors:
Open Access
- 11 November 2024
- journal article
- research article
- Published by Springer Nature in Digestive Diseases and Sciences
- Vol. 70 (5) , 1637-1645
Abstract
Background The fecal immunochemical test for hemoglobin (FIT) is now a widely used non-invasive test in population-based organized screening programs for colorectal neoplasia. The positivity thresholds of tests currently in use are based on the fecal hemoglobin concentration (f-Hb), but the rationale for the adopted thresholds are not well documented. To understand current global usage of FIT in screening programs we conducted an international survey of the brands of FIT used, the f-Hb positivity threshold applied and the rationale for the choice. Methods All members of the World Endoscopy Organization CRC Screening Committee were invited to complete an eight-element initial electronic survey exploring the key aims. Responses were obtained from 63 individuals, representing 38 specific locations in 28 countries. A follow-up survey on technical issues was offered to the 38 locations, with replies from 17 sites in 13 countries. Results In-use quantitative FIT were provided by four main manufacturers; Minaris Medical (2 countries), Eiken Chemical Company/Polymedco (21), Alfresa Pharma (2) and Sentinel Diagnostics (4). Of the 38 screening sites, 15 used the threshold of 20 µg hemoglobin/g feces, while thresholds ranged between 8.5 and 120 ug/g in the remainder. Seven explanations were given for adopted FIT thresholds; maximizing the sensitivity for colorectal neoplasia (n = 23) was the most common followed by the availability of colonoscopy resources (n = 18). Predictive value, specificity, and cost effectiveness were less frequently reported as the rationale. Nine sites found it necessary to change the threshold that they had initially selected. Conclusions This international survey has documented the wide range of FIT positivity thresholds that are in current use. Quantitative FITs enable programs to achieve the desired program outcomes within available resource constraints by adjusting the positivity threshold. This supports the need for enabling positivity threshold adjustment of emerging new screening tests based on novel predictive biomarkers, rather than providing inflexible test endpoints.Keywords
Funding Information
- Flinders University
This publication has 23 references indexed in Scilit:
- An efficient strategy for evaluating new non-invasive screening tests for colorectal cancer: the guiding principlesGut, 2023
- Faecal immunochemical tests for haemoglobin: Analytical challenges and potential solutionsClinica Chimica Acta, 2021
- Screening for Colorectal CancerJAMA, 2021
- Performance of two faecal immunochemical tests for the detection of advanced neoplasia at different positivity thresholds: a cross-sectional study of the Dutch national colorectal cancer screening programmeThe Lancet Gastroenterology & Hepatology, 2019
- Colorectal cancer screening: a global overview of existing programmesGut, 2015
- Advances in Fecal Occult Blood Tests: The FIT RevolutionDigestive Diseases and Sciences, 2014
- Immunochemical Fecal Occult Blood Testing Is Equally Sensitive for Proximal and Distal Advanced NeoplasiaAmerican Journal of Gastroenterology, 2012
- A Proposal to Standardize Reporting Units for Fecal Immunochemical Tests for HemoglobinJNCI: Journal of the National Cancer Institute, 2012
- Performance of immunochemical faecal occult blood test in colorectal cancer screening in average‐risk population according to positivity threshold and number of samplesInternational Journal of Cancer, 2009
- A Quantitative Immunochemical Fecal Occult Blood Test for Colorectal NeoplasiaAnnals of Internal Medicine, 2007