Correcting pulse duration effects in the diffusional kurtosis of the multi‐compartment Kärger model
Open Access
- 10 June 2025
- journal article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (5) , 2249-2257
Abstract
Purpose: To demonstrate a method of reducing pulse duration effects for the diffusional kurtosis of the multi‐compartment Kärger model (KM) as estimated with a Stejskal‐Tanner DWI sequence.Theory and Methods: An effective diffusion time is introduced that corrects errors in the apparent diffusional kurtosis arising from a nonzero pulse duration δ for the multi‐compartment KM. The correction is exact to first order in the diffusion time Δ, and numerical calculations are used to assess how well it reduces pulse duration effects. Specifically, for the two‐compartment KM, the deviations of the apparent kurtosis obtained with the Stejskal‐Tanner sequence from the exact kurtosis are calculated for the full range of δ and Δ, and similar calculations are performed for the deviation in the derivative of the kurtosis with respect to Δ. For the general multi‐compartment KM, upper bounds on the maximum magnitude of the deviations are determined. Application of the correction to estimation of intercompartmental exchange rates is illustrated with several examples.Results: For the two‐compartment KM, the correction reduces the deviation of the apparent kurtosis and its time derivative for most values of δ and Δ. For the general multi‐compartment KM, the maximum deviation magnitude, relative to the initial kurtosis, is 2.26% for the uncorrected kurtosis and 0.57% after correction. The correction reduces the maximum deviation magnitude of the derivative from 46% to less than 1%.Conclusion: Pulse duration effects for the kurtosis of the multi‐compartment KM can be strongly suppressed by applying the effective diffusion time correction.Keywords
Funding Information
- National Institute on Aging (R01AG054159, R01AG057602)
This publication has 29 references indexed in Scilit:
- Romer‐ EPTI : Rotating‐view motion‐robust super‐resolution EPTI for SNR ‐efficient distortion‐free in‐vivo mesoscale diffusion MRI and microstructure imagingMagnetic Resonance in Medicine, 2024
- Diffusional kurtosis time dependence and the water exchange rate for the multi‐compartment Kärger modelMagnetic Resonance in Medicine, 2023
- Measuring water exchange on a preclinical MRI system using filter exchange and diffusion time dependent kurtosis imagingMagnetic Resonance in Medicine, 2022
- Time‐dependent diffusivity and kurtosis in phantoms and patients with head and neck cancerMagnetic Resonance in Medicine, 2022
- Time dependence in diffusion MRI predicts tissue outcome in ischemic stroke patientsMagnetic Resonance in Medicine, 2021
- A complete derivation of the Kärger equations for analyzing NMR diffusion measurements of exchanging systemsConcepts in Magnetic Resonance Part A, 2018
- Monte Carlo study of a two‐compartment exchange model of diffusionNMR in Biomedicine, 2010
- MRI quantification of non‐Gaussian water diffusion by kurtosis analysisNMR in Biomedicine, 2010
- Diffusional kurtosis imaging: The quantification of non‐gaussian water diffusion by means of magnetic resonance imagingMagnetic Resonance in Medicine, 2005
- Reduction of eddy‐current‐induced distortion in diffusion MRI using a twice‐refocused spin echoMagnetic Resonance in Medicine, 2002