Use of a custom alignment guide to improve glenoid component position in total shoulder arthroplasty
- 30 August 2012
- journal article
- shoulder
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 21 (12) , 2860-2866
Abstract
Purpose: Total and reverse total shoulder arthroplasty (TSA) are used to treat patients with glenohumeral joint osteoarthritis. The revision rate remains high compared with hip and knee arthroplasty. Glenoid component loosening is an important complication and may be caused by poor positioning of the component. We aimed to evaluate the safety and accuracy of a custom glenoid jig created using preoperative computed tomography (CT) imaging with 3D modelling for glenoid component implantation.Methods: Preoperative CT scans of each shoulder (N = 7) were obtained. Implants were virtually aligned and custom templates were created for intraoperative use. A two‐part custom jig was manufactured for alignment of the central peg and the peripheral screws. Three‐dimensional orientation of the component and screws was evaluated in postoperative CT scans. The difference between the preoperative plan and the result was then calculated.Results: No technical difficulties or complications occurred. The mean absolute difference between the planned alignment and the postoperative placement of the glenoid component in the three‐dimensional space was 3.4 mm (SD = 1 mm). The total average difference for all screws (N = 10) was 6.3° (SD = 3.2°).Conclusion: A CT‐based custom glenoid component alignment can reliably guide the placement of the glenoid component during conventional and reverse TSA. This custom jig may be useful for optimizing glenoid component position in the setting of reverse and TSA.Level of evidence: IV.Keywords
This publication has 28 references indexed in Scilit:
- The effect of component positioning on intrinsic stability of the reverse shoulder arthroplastyJournal of Shoulder and Elbow Surgery, 2010
- Survivorship of the humeral component in shoulder arthroplastyJournal of Shoulder and Elbow Surgery, 2010
- Improved accuracy of computer assisted glenoid implantation in total shoulder arthroplasty: An in-vitro randomized controlled trialJournal of Shoulder and Elbow Surgery, 2009
- Glenoid morphology in reverse shoulder arthroplasty: Classification and surgical implicationsJournal of Shoulder and Elbow Surgery, 2009
- Survival of the glenoid component in shoulder arthroplastyJournal of Shoulder and Elbow Surgery, 2009
- Improved accuracy of glenoid positioning in total shoulder arthroplasty with intraoperative navigation: A prospective-randomized clinical studyJournal of Shoulder and Elbow Surgery, 2009
- Computer navigation in total hip replacement: a meta-analysisInternational Orthopaedics, 2008
- Treatment of Painful Pseudoparesis Due to Irreparable Rotator Cuff Dysfunction with the Delta III Reverse-Ball-and-Socket Total Shoulder ProsthesisJournal of Bone and Joint Surgery, 2005
- Initial glenoid component fixation in “reverse” total shoulder arthroplasty: A biomechanical evaluationJournal of Shoulder and Elbow Surgery, 2005
- The glenoid component in total shoulder arthroplastyJournal of Shoulder and Elbow Surgery, 1993