Abstract
This paper presents a PVT-robust error-feedback (EF) noise-shaping SAR (NS-SAR) ADC for direct neural-signal recording. For closed-loop bidirectional neural interfaces enabling the next generation neurological devices, a wide-dynamic-range neural recording circuit is required to accommodate stimulation artifacts. A recording structure using an NS-SAR ADC can be a good candidate because the high resolution and wide dynamic range can be obtained with a low oversampling ratio and power consumption. However, NS-SAR ADCs require an additional gain stage to obtain a well-shaped noise transfer function (NTF), and a dynamic amplifier is often used as the gain stage to minimize power overhead at the cost of vulnerability to PVT variations. To overcome this limitation, the proposed work reutilizes the capacitive-feedback amplifier, which is the analog front-end of the neural recording circuit, as a PVT-robust gain stage to achieve a reliable NS performance. In addition, a new chopper-based implementation of a passive high-pass IIR filter is proposed, achieving an improved NTF compared to prior EF NS-SAR ADCs. Fabricated in a 180-nm CMOS process, the proposed NS-SAR ADC consumes 4.3-μW power and achieves a signal-to-noise-and-distortion ratio (SNDR) of 71.7 dB and 82.7 dB for a bandwidth of 5 kHz and 300 Hz, resulting in a Schreier figure of merit (FOM) of 162.4 dB and 162.1 dB, respectively. Direct neural recording using the proposed NS-SAR ADC is demonstrated successfully in vivo , and also its tolerance against stimulation artifacts is validated in vitro .Keywords
Funding Information
- National Research Foundation of Korea
- Ministry of Science and ICT (MSIT), Korea (2021M3F3A2A01037365, 2020M3C1B8A01111568)
- Information Technology Research Center
- Institute of Information and Communications Technology Planning and Evaluation (IITP), Korea
- MSIT, Korea (IITP-2020-0-01778)
- IDEC, Korea
This publication has 49 references indexed in Scilit:
- Closed-loop Neurostimulation: The Clinical ExperienceNeurotherapeutics, 2014
- Closed-loop cortical neuromodulation in Parkinson’s disease: An alternative to deep brain stimulation?Clinical Neurophysiology, 2014
- A 0.45 V 100-Channel Neural-Recording IC With Sub-$\mu {\rm W}$/Channel Consumption in 0.18 $\mu{\rm m}$ CMOSIEEE Transactions on Biomedical Circuits and Systems, 2013
- A 26 $\mu$W 8 bit 10 MS/s Asynchronous SAR ADC for Low Energy RadiosIEEE Journal of Solid-State Circuits, 2011
- Electrical stimulation of the anterior nucleus of thalamus for treatment of refractory epilepsyEpilepsia, 2010
- Translational principles of deep brain stimulationNature Reviews Neuroscience, 2007
- A low-power low-noise cmos for amplifier neural recording applicationsIEEE Journal of Solid-State Circuits, 2003
- Effects of Posture on Stimulation Parameters in Spinal Cord StimulationNeuromodulation: Technology at the Neural Interface, 1998
- Postural Changes in Spinal Cord Stimulation Perceptual ThresholdsNeuromodulation: Technology at the Neural Interface, 1998
- Multifactorial Analysis of Epidural Spinal Cord StimulationStereotactic and Functional Neurosurgery, 1991