Abstract
Deep penetration of distributed generators have created several stability and operation issues for power systems. In order to address these, inverters with advanced capabilities such as frequency and reactive power support the grid. Known also as Smart Inverters (SIs), these devices are highly dynamic and contribute to the power flow in the system. Notwithstanding their benefits, such dynamic devices are new to distribution networks. Power system operators are very reluctant toward such changes as they may cause unknown issues. In order to alleviate these concerns and facilitate SIs integration to the grid, behavior studies are required. To that end, this paper presents a power hardware-in-the-loop test set up and tests that are performed to study fault behavior of SIs connected to distribution networks. The details of the software model, SI integration with the real-time simulator, test results, and their analyses are presented. This experience shows that it is not trivial to connect such novel devices with simulation environments. Adjustments are required on both software and hardware fronts on a case-by-case basis. The encountered integration issues and their solutions are presented herein. The fault behavior of the SI with respect to the fault location is documented. It is observed that for faults that are close to SIs, momentary cessation of generation is observed. This needs to be tackled by device manufacturers as this phenomenon is very detrimental to health of a power system under fault conditions. Extensive PHIL test results show that several factors affect the fault behavior of an SI: fault location and its duration, SI mode of operation as well as extra devices housed in the casing. These results and their in-depth analyses are presented for a thorough understanding of SI behavior under fault conditions.Keywords
This publication has 20 references indexed in Scilit:
- Optimization of Voltage Unbalance Compensation by Smart InverterEnergies, 2020
- Grid-Connected PV Generation System—Components and Challenges: A ReviewEnergies, 2020
- A Mixed Integer Linear Programming Based Load Shedding Technique for Improving the Sustainability of Islanded Distribution SystemsSustainability, 2020
- Advanced Laboratory Testing Methods Using Real-Time Simulation and Hardware-in-the-Loop Techniques: A Survey of Smart Grid International Research Facility Network ActivitiesEnergies, 2020
- Microgrid Controller Testing Using Power Hardware-in-the-LoopEnergies, 2020
- A Review of Strategies to Increase PV Penetration Level in Smart GridsEnergies, 2020
- Design and Performance Analysis of a Stand-alone PV System with Hybrid Energy Storage for Rural IndiaElectronics, 2019
- Cybersecurity Risk Assessment for California's Smart Inverter Functions2019
- Analysis of Smart Inverter’s Impact on the Distribution Network OperationIEEE Access, 2019
- Design and Line Fault Protection Scheme of a DC Microgrid Based on Battery Energy Storage SystemEnergies, 2018