Diagonal Compression Tests on Unfired and Fired Masonry Wallettes Retrofitted with Textile-Reinforced Alkali-Activated Mortar
Open Access
- 29 December 2023
- journal article
- research article
- Published by MDPI AG in Journal of Composites Science
- Vol. 8 (1) , 14
Abstract
This paper discusses the integration of an alkali-activated mortar (AAM), based on industrial waste, into a novel composite material fit for structural upgrading purposes and rendered with high temperature endurance and a low CO2 footprint. The AAM combined with carbon fiber textiles form a new generation of sustainable inorganic matrix composites—that of textile-reinforced alkali-activated mortars (TRAAM). A test program was designed to assess the effectiveness of carbon TRAAM overlays in increasing the shear capacity of masonry wall specimens comprising solid clay bricks bonded with lime-based mortar and furnished with TRAAM jackets on both sides. The initial and the residual capacity of the reinforced walls were evaluated, the latter by performing diagonal compression tests after exposure to 300 °C and 550 °C. It was shown that TRAAM jacketing can increase the shear capacity of unfired masonry walls by 260% and 335% when a single or a double layer of textile is used, respectively. Rapid heating to temperatures up to 550 °C, one-hour-long steady-state heating, and natural cooling bore no visible thermal cracks on the specimens and had little effect on their residual capacity. Based on these results, the prospect of using TRAAM for retrofitting applications for fire-resilient structures seems very auspicious.Keywords
Funding Information
- European Union’s H2020 MARIE SKODOWSKA-CURIE ACTIONS (813596 DuRSAAM)
This publication has 39 references indexed in Scilit:
- Utilisation of FeNi-Slag for the Production of Inorganic Polymeric Materials for Construction or for Passive Fire ProtectionWaste and Biomass Valorization, 2013
- In-plane behaviour of tuff masonry strengthened with inorganic matrix–grid compositesComposites Part B: Engineering, 2013
- Masonry exposed to high temperatures: Mechanical behaviour and properties—An overviewFire Safety Journal, 2013
- Mechanical behaviour of full unit masonry panels under fire actionFire Safety Journal, 2011
- Textile Reinforced Mortar at High TemperaturesApplied Mechanics and Materials, 2011
- Experimental and Theoretical Investigation on Masonry after High Temperature ExposureExperimental Mechanics, 2011
- Innovation in use and research on cementitious materialCement and Concrete Research, 2008
- The role of inorganic polymer technology in the development of ‘green concrete’Cement and Concrete Research, 2007
- Geopolymerisation of low calcium ferronickel slagsJournal of Materials Science, 2006
- Textile-reinforced mortar (TRM) versus FRP as strengthening material of URM walls: in-plane cyclic loadingMaterials and Structures, 2006