Left ventricular volume measurement in mice by conductance catheter: evaluation and optimization of calibration
Authors:
- Jan Møller NielsenJNJan Møller Nielsen
- Steen B. KristiansenSKSteen B. Kristiansen
- Steffen RinggaardSRSteffen Ringgaard
- Torsten Toftegaard NielsenTNTorsten Toftegaard Nielsen
- Allan FlyvbjergAFAllan Flyvbjerg
- Andrew N. RedingtonARAndrew N. Redington
- Hans Erik BøtkerHBHans Erik Bøtker
- 1 July 2007
- journal article
- research article
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 293 (1) , H534-H540
Abstract
The conductance catheter (CC) allows thorough evaluation of cardiac function because it simultaneously provides measurements of pressure and volume. Calibration of the volume signal remains challenging. With different calibration techniques, in vivo left ventricular volumes (VCC) were measured in mice ( n = 52) with a Millar CC (SPR-839) and compared with MRI-derived volumes (VMRI). Significant correlations between VCC and VMRI [end-diastolic volume (EDV): R2 = 0.85, P < 0.01; end-systolic volume (ESV): R2 = 0.88, P < 0.01] were found when injection of hypertonic saline in the pulmonary artery was used to calibrate for parallel conductance and volume conversion was done by individual cylinder calibration. However, a significant underestimation was observed [EDV = −17.3 μl (−22.7 to −11.9 μl); ESV = −8.8 μl (−12.5 to −5.1 μl)]. Intravenous injection of the hypertonic saline bolus was inferior to injection into the pulmonary artery as a calibration method. Calibration with an independent measurement of stroke volume decreased the agreement with VMRI. Correction for an increase in blood conductivity during the in vivo experiments improved estimation of EDV. The dual-frequency method for estimation of parallel conductance failed to produce VCC that correlated with VMRI. We conclude that selection of the calibration procedure for the CC has significant implications for the accuracy and precision of volume estimation and pressure-volume loop-derived variables like myocardial contractility. Although VCC may be underestimated compared with MRI, optimized calibration techniques enable reliable volume estimation with the CC in mice.Keywords
This publication has 24 references indexed in Scilit:
- How to Perform an Accurate Assessment of Cardiac Function in Mice using High-Resolution Magnetic Resonance ImagingJournal of Cardiovascular Magnetic Resonance, 2006
- Nonlinear Conductance-Volume Relationship for Murine Conductance Catheter Measurement SystemIEEE Transactions on Biomedical Engineering, 2005
- Direct comparison of magnetic resonance imaging and conductance microcatheter in the evaluation of left ventricular function in miceBasic Research in Cardiology, 2005
- Improved Quantification of Left Ventricular Volumes and Mass Based on Endocardial and Epicardial Surface Detection from Cardiac MR Images Using Level Set ModelsJournal of Cardiovascular Magnetic Resonance, 2005
- Myocardial blood flow mapping in mice using high‐resolution spin labeling magnetic resonance imaging: Influence of ketamine/xylazine and isoflurane anesthesiaMagnetic Resonance in Medicine, 2005
- Comparison of intravenous and pulmonary artery injections of hypertonic saline for the assessment of conductance catheter parallel conductanceCardiovascular Research, 2000
- Dependence of anisotropic myocardial electrical resistivity on cardiac phase and excitation frequencyBasic Research in Cardiology, 1994
- Continuous measurement of left ventricular volume in animals and humans by conductance catheter.Circulation, 1984
- Electrical properties of blood and its constitutents: Alternating current spectroscopyAnnals of Hematology, 1983
- A NOTE ON NORMAL CORRELATIONBiometrika, 1939