Review of Robotic Technology for Stereotactic Neurosurgery
- 30 April 2015
- journal article
- review article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Reviews in Biomedical Engineering
- Vol. 8 (19373333) , 125-137
Abstract
The research of stereotactic apparatus to guide surgical devices began in 1908, yet a major part of today's stereotactic neurosurgeries still rely on stereotactic frames developed almost half a century ago. Robots excel at handling spatial information, and are, thus, obvious candidates in the guidance of instrumentation along precisely planned trajectories. In this review, we introduce the concept of stereotaxy and describe a standard stereotactic neurosurgery. Neurosurgeons' expectations and demands regarding the role of robots as assistive tools are also addressed. We list the most successful robotic systems developed specifically for or capable of executing stereotactic neurosurgery. A critical review is presented for each robotic system, emphasizing the differences between them and detailing positive features and drawbacks. An analysis of the listed robotic system features is also undertaken, in the context of robotic application in stereotactic neurosurgery. Finally, we discuss the current perspective, and future directions of a robotic technology in this field. All robotic systems follow a very similar and structured workflow despite the technical differences that set them apart. No system unequivocally stands out as an absolute best. The trend of technological progress is pointing toward the development of miniaturized cost-effective solutions with more intuitive interfaces.Keywords
Funding Information
- NETT (FP7-PEOPLE-2011-ITN-289146)
- ACTIVE Project (FP7-ICT-2009-6-270460)
- FCT (SFRH/BD/86499/2012)
This publication has 73 references indexed in Scilit:
- Automatic Trajectory Planner for StereoElectroEncephaloGraphy Procedures: A Retrospective StudyIEEE Transactions on Biomedical Engineering, 2012
- Telecontrolled micromanipulator system (NeuRobot) for minimally invasive neurosurgery2006
- System integration of NeuroBot: a skull-base surgical robotic system2005
- Clinical evaluation of stereotactic brain biopsies with an MKM-mounted instrument holderActa Neurochirurgica, 2003
- Micromanipulator system (NeuRobot): clinical application in neurosurgeryInternational Congress Series, 2003
- Simulating minimally invasive neurosurgical interventions using an active manipulatorInternational Congress Series, 2002
- An MKM-mounted instrument holder for frameless point-stereotactic procedures: a phantom-based accuracy evaluationJournal of Neurosurgery, 2001
- Frameless Stereotactic-Directed Tissue Sampling During Surgery of Suspected Low-Grade Gliomas to Avoid Histological Undergradingmin - Minimally Invasive Neurosurgery, 1998
- Image-guided stereotactic neurosurgery with the multicoordinate manipulator microscopeSurgical Neurology, 1997
- Contour-Guided Brain Tumor Surgery Using a Stereotactic Navigating MicroscopeStereotactic and Functional Neurosurgery, 1997