Controlled E-field gradient coils
Authors:
- 31 October 2003
- journal article
- research article
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 16 (3) , 113-120
Abstract
Peripheral neural stimulation is a major problem in current gradient coil designs. Induced current problems in patients relate directly to gradient strength and modulation frequency. Current designs of gradient coil tend to limit ultra-high-speed imaging methods such as echo-planar imaging through the effect of induced currents which produce tingling sensations and involuntary muscle twitch. Neural stimulation could also trigger epileptic fits and/or cardiac fibrillation. For reduction of induced currents, an important aspect is the coil geometry. It is desirable to design the gradient coil in such a way as to prevent closed loop circulating currents within the body. Preliminary results using a four-sector gradient coil with rectangular geometry, operating in a low mutual coupling mode, indicate significant reduction in the E-field within the subject volume of the coil. Reduction in induced currents in the patient allows safer operation at higher magnetic field strengths together with faster scans currently prohibited through neural stimulation effects in standard coil geometries.Keywords
This publication has 14 references indexed in Scilit:
- Magnetization transfer short inversion time inversion recovery enhanced 1H MRI of the human lung.Magnetic Resonance Materials in Physics, Biology and Medicine, 2002
- Gradient system providing continuously variable field characteristicsMagnetic Resonance in Medicine, 2002
- Simple linear formulation for magnetostimulation specific to MRI gradient coilsMagnetic Resonance in Medicine, 2001
- The AAPM/RSNA Physics Tutorial for ResidentsRadioGraphics, 1999
- Peripheral nerve stimulation in a whole‐body echo‐planar imaging systemJournal of Magnetic Resonance Imaging, 1997
- Theoretical evaluation of peripheral nerve stimulation during MRI with an implanted spinal fusion stimulatorMagnetic Resonance Imaging, 1997
- Avoiding peripheral nerve stimulation: Gradient waveform criteria for optimum resolution in echo‐planar imagingMagnetic Resonance in Medicine, 1994
- Limits to neural stimulation in echo‐planar imagingMagnetic Resonance in Medicine, 1993
- The National Radiological Protection Boardad hocAdvisory Group on Nuclear Magnetic Resonance Clinical ImagingBritish Journal of Radiology, 1983
- Magnetic field gradient coils for NMR imagingJournal of Physics E: Scientific Instruments, 1982