Quantitation of Right Ventricular Volumes and Ejection Fraction by Three‐Dimensional Echocardiography in Patients: Comparison with Magnetic Resonance Imaging and Radionuclide Ventriculography
- 28 June 2006
- journal article
- research article
- Published by Wiley in Echocardiography
- Vol. 23 (8) , 666-680
Abstract
Three‐dimensional echocardiography (3DE) provides volumetric measurements without geometric assumptions. Volume‐rendered 3DE has been shown to be accurate for the measurement of right ventricular (RV) volumes in vitro and in animal studies; however, few data are available regarding its accuracy in patients. This study examined the accuracy of 3DE for quantitation of RV volumes and ejection fraction (EF) in patients, compared to magnetic resonance imaging (MRI) and radionuclide ventriculography (RNV). Twenty patients underwent MRI, gated equilibrium RNV, and 3DE using rotational acquisition from both the transesophageal and transthoracic approaches. RV volumes and EF were calculated from the 3DE data using multislice analysis (true Simpson's rule). RV volumes calculated by MRI (end‐diastolic volume (EDV) 109.4 ± 34.3 mls, end‐systolic volume (ESV) 59.6 ± 31.0 mls, and EF 47.7 ± 17.1%) agreed closely with 3DE. For transesophageal echocardiography, EDV was 108.1 ± 29.7 mls (r = 0.86, mean difference 1.3 ± 17.8 mls); ESV was 62.5 ± 23.8 mls (r = 0.85, mean difference 2.8 ± 15.1 mls); and EF was 43.2 ± 11.7% (r = 0.84, mean difference 4.5 ± 9.7%). For transthoracic echocardiography, EDV was 107.7 ± 27.5mls (r = 0.85, mean difference 1.6 ± 18.2mls); ESV was 59.7 ± 22.1 mls (r = 0.93, mean difference 3.2 ± 19.6 mls); and EF was 45.2 ± 11.5% (r = 0.86, mean difference 2.0 ± 9.4%). There were close correlations, small mean differences and narrow limits of agreement between RNV‐derived EF (43.4 ± 12.1%) and both transesophageal (r = 0.95 mean difference 0.2 ± 3.7%) and transthoracic 3DE (r = 0.95, mean difference 1.8 ± 5.4%). Three‐dimensional echocardiography is a promising new method of calculating RV volumes and EF, comparing well with MRI and RNV. The accuracy of transthoracic 3DE was comparable to that of the transesophageal approach. Three‐dimensional echocardiography has the potential to be useful in the clinical assessment of RV disorders.Keywords
This publication has 47 references indexed in Scilit:
- Quantification of right ventricular function with magnetic resonance imaging in children with normal hearts and with congenital heart diseaseAmerican Heart Journal, 1995
- Evaluation of cardiac function with magnetic resonance imagingAmerican Heart Journal, 1994
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Validation of attenuation-corrected equilibrium radionuclide angiographic determinations of right ventricular volume: comparison with cast-validated biplane cineventriculography.Circulation, 1985
- Right ventricular function in coronary artery disease as assessed by two-dimensional echocardiographyAmerican Heart Journal, 1984
- Assessment of right ventricular function using two-dimensional echocardiographyAmerican Heart Journal, 1984
- Echocardiographic measurement of right ventricular volume.Circulation, 1984
- A new two-dimensional echocardiographic technique for evaluating right ventricular size and performance in patients with obstructive lung disease.Circulation, 1982
- A new technique for assessing right ventricular ejection fraction using rapid multiple-gated equilibrium cardiac blood pool scintigraphy. Description, validation and findings in chronic coronary artery disease.Circulation, 1979
- Determination of right atrial and right ventricular size by two-dimensional echocardiography.Circulation, 1979