Abstract
Objective: To evaluate the technical success of contrast-enhanced ultrasound (CEUS)-guided biopsy of poorly visualized liver lesions. Materials and Methods: In this IRB-approved, HIPAA-compliant retrospective study, 10 patients who received CEUS-guided biopsy indicated by sub-optimal visualization of liver lesion by B-mode ultrasound from January 2015 to December 2015 were analyzed. None of the patients had cirrhotic livers. Definity contrast (Lantheus Medical Imaging) was used in all cases. All procedures were done under moderate conscious sedation except for one case which required general anesthesia with Propofol. Technical success was defined as sufficient tissue sampling that demonstrated histopathological concordance with imaging findings, thus providing definitive diagnosis without need for re-biopsy. Size and location of liver lesions, amount of contrast, procedure time, complications, and final histopathology were recorded for each case. Results: CEUS-guided biopsy resulted in technical success in 7 of 10 cases (70%). All patients tolerated the procedure well with no peri-procedural complications. Average dose of Definity given was 0.83 ± 0.13 mL, with procedure time of 32 ±14 minute. In the 3 cases that required re-biopsy, liver lesions were located in segments 2, 6, and 6, with maximum diameters of 1.1, 1.5, and 1.1 cm, respectively. Conclusion: CEUS-guided biopsy was shown to be a feasible, safe, and efficient method of acquiring tissue sample from liver lesions that were otherwise poorly visualized by standard gray-scale ultrasound (Fig. 1). High technical success rate was achieved in this initial experience.