Study on the reaction mechanism and the static injection chemiluminescence method for detection of acetaminophen
- 14 February 2013
- journal article
- research article
- Published by Wiley in Luminescence
- Vol. 28 (6) , 905-909
Abstract
Acetaminophen, also called paracetamol, is found in Tylenol, Excedrin and other products as over–the‐counter medicines. In this study, acetaminophen as a luminol signal enhancer was used in the chemiluminescence (CL) substrate solution of horseradish peroxidase (HRP) for the first time. The use of acetaminophen in the luminol–HRP–H2O2 system affected not only the intensity of the obtained signal, but also its kinetics. It was shown that acetaminophen was to be a potent enhancer of the luminol–HRP–H2O2 system. A putative enhancement mechanism for the luminol–H2O2–HRP–acetaminophen system is presented. The resonance of the nucleophilic amide group and the benzene ring of acetaminophen structure have a great effect on O‐H bond dissociation energy of the phenol group and therefore on phenoxyl radical stabilization. These radicals act as mediators between HRP and luminol in an electron transfer reaction that generates luminol radicals and subsequently light emission, in which the intensity of CL is enhanced in the presence of acetaminophen. In addition, a simple method was developed to detect acetaminophen by static injection CL based on the enhanced CL system of luminol–H2O2–HRP by acetaminophen. Experimental conditions, such as pH and concentrations of substrates, have been examined and optimized. The proposed method exhibited good performance, the linear range was from 0.30 to 7.5 mM, the relative standard deviation was 1.86% (n = 10), limit of detection was 0.16 mM and recovery was 99 ± 4%. Copyright © 2013 John Wiley & Sons, Ltd.Keywords
This publication has 16 references indexed in Scilit:
- Acetaminophen: Safe Use and Associated RisksThe Journal of Hand Surgery, 2009
- Chemiluminescence immunoassayTrAC Trends in Analytical Chemistry, 2009
- Sensitive determination of phenothiazines in pharmaceutical preparation and biological fluid by flow injection chemiluminescence method using luminol–KMnO4 systemTalanta, 2007
- Effect of the luminol signal enhancer selection on the curve parameters of an immunoassay and the chemiluminescence intensity and kineticsTalanta, 2007
- Development of a Micro Total Analysis System Incorporating Chemiluminescence Detection and Application to Detection of Cancer MarkersAnalytical Chemistry, 2005
- Employment of 4-(1-imidazolyl)phenol as a luminol signal enhancer in a competitive-type chemiluminescence immunoassay and its comparison with the conventional antigen–horseradish peroxidase conjugate-based assayAnalytica Chimica Acta, 2004
- Lophine derivatives and analogues as new phenolic enhancers for the luminol–hydrogen peroxide–horseradish peroxidase chemiluminescence systemAnalytica Chimica Acta, 2000
- Relation between the structure of some heterocyclic derivatives and other compounds, and their effects as enhancers or inhibitors of the luminol-H2O2-horseradish peroxidase chemiluminescenceJournal of Photochemistry and Photobiology A: Chemistry, 1997
- A Density Functional Study of Substituent Effects on the O−H and O−CH3 Bond Dissociation Energies in Phenol and AnisoleThe Journal of Organic Chemistry, 1996
- Chemiluminescence of LUminol and Related Hydrazides: The Light Emission StepJournal of the American Chemical Society, 1964