The Influence of Acupressure on the Monitoring of Acoustic Evoked Potentials in Unsedated Adult Volunteers
Authors:
- Alexander DullenkopfADAlexander Dullenkopf
- Achim SchmitzASAchim Schmitz
- Goran LamesicGLGoran Lamesic
- Markus WeissMWMarkus Weiss
- Anette LangALAnette Lang
- 1 October 2004
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 99 (4) , 1147-1151
Abstract
Approaches for monitoring depth of anesthesia can be influenced by things other than anesthetics. In this study, we evaluated the influence of acupressure on the A-line autoregressive index (AAI) and on stress levels in unsedated volunteers. Fifteen unsedated adult volunteers received pressure on the acupuncture Extra 1 point (EP) and on a control point for 10 min on different days. AAI was recorded 5 min before, during, and 5 min after the interventions. Before and after the procedures, the volunteers quantified their level of stress by means of a visual analog stress scale (VSS; 0-100). Corresponding data were compared by Wilcoxon's signed rank test (Bonferroni correction, P < 0.05). Data are median (range). AAI decreased from 73 (40-99) to 53 (33-94) after 10 min of pressure on EP (P = 0.0044). Five minutes after release of pressure there was no difference compared with initial values. There was a statistically significant difference between VSS before and after pressure on EP (36 [7-67] to 15 [0-44]; P = 0.0066), but not on control point. In conclusion, there was a wide range of AAI values in awake volunteers. The AAI was influenced by acupressure performed on the EP in unsedated adult volunteers. Acupressure on this point significantly reduced stress levels.Keywords
This publication has 21 references indexed in Scilit:
- Comparison of Alaris AEP index and bispectral index during propofol-remifentanil anaesthesia †British Journal of Anaesthesia, 2003
- The Bispectral Index Declines During Neuromuscular Block in Fully Awake PersonsAnesthesia & Analgesia, 2003
- ARX-Derived Auditory Evoked Potential Index and Bispectral Index During the Induction of Anesthesia with Propofol and RemifentanilAnesthesia & Analgesia, 2003
- Correlation of Approximate Entropy, Bispectral Index, and Spectral Edge Frequency 95 (SEF95) with Clinical Signs of “Anesthetic Depth” during Coadministration of Propofol and RemifentanilAnesthesiology, 2003
- Pressure Applied on the Extra 1 Acupuncture Point Reduces Bispectral Index Values and Stress in VolunteersAnesthesia & Analgesia, 2003
- Relationship between bispectral index, auditory evoked potential index and effect-site EC 50 for propofol at two clinical end-points †British Journal of Anaesthesia, 2003
- Mechanisms of Intraoperative Brainstem Auditory Evoked Potential ChangesJournal Of Clinical Neurophysiology, 2002
- Comparison of auditory evoked potentials and the A‐line ARX Index for monitoring the hypnotic level during sevoflurane and propofol inductionActa Anaesthesiologica Scandinavica, 2002
- Computerized EEG monitoring of anesthetic depth: Quo Vadis?Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 2000
- Quantitative EEG in assessment of anaesthetic depth: comparative study of methodologyBritish Journal of Anaesthesia, 1996