Abstract
Two-phase cooling has become a promising method for improving the sustainability and efficiency of high energy-density and power-density devices. Fundamentally, however, two-phase thermal transport is not well understood for local, transient processes, especially at critical to near-critical heat fluxes at the macro, micro, and nano-scales. Here we report spatiotemporal characterization of the single-bubble ebullition cycle in a hot-spot heating configuration with heat fluxes approaching 3 kW cm−2. In particular, we experimentally reconstruct the spatiotemporal heat transfer coefficient in terms of its proportionality at both the macro-scale (l >> 1 μm) and the micro-to-nanoscale (l < 1 μm). We show that the maximum rates of heat transfer occur during the microlayer evaporation stage of the ebullition cycle, corresponding to critical maxima in the heat transfer coefficient of ~160 ± 40 kW m−2 K−1 and ~5300 ± 300 kW m−2 K−1 at the macro-scale and micro-to-nanoscale, respectively.Keywords
This publication has 52 references indexed in Scilit:
- The material dependence of temperature measurement resolution in thermal scanning electron microscopyApplied Physics Letters, 2013
- On-chip two-phase cooling of datacenters: Cooling system and energy recovery evaluationApplied Thermal Engineering, 2012
- Characterization and Modeling of the Heat Transfer Performance of Nanostructured Cu Micropost WicksJournal of Heat Transfer, 2011
- Measurement of the temperature non-uniformity in a microchannel heat sink using microscale laser-induced fluorescenceInternational Journal of Heat and Mass Transfer, 2010
- Experimental study of biporous wicks for high heat flux applicationsInternational Journal of Heat and Mass Transfer, 2009
- Single-Phase and Two-Phase Hybrid Cooling Schemes for High-Heat-Flux Thermal Management of Defense ElectronicsJournal of Electronic Packaging, 2009
- Two-phase flow in high-heat-flux micro-channel heat sink for refrigeration cooling applications: Part II—heat transfer characteristicsInternational Journal of Heat and Mass Transfer, 2005
- A study of the effects of heater size, subcooling, and gravity level on pool boiling heat transferInternational Journal of Heat and Fluid Flow, 2004
- Interfacial heat transfer during subcooled flow boilingInternational Journal of Heat and Mass Transfer, 2002
- Assessment of high-heat-flux thermal management schemesIEEE Transactions on Components and Packaging Technologies, 2001