Magnetic resonance imaging assessment of fibrovascular ingrowth into porous polyethylene orbital implants
Authors:
- 1 May 2006
- journal article
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 34 (4) , 354-359
Abstract
Background: To evaluate fibrovascular ingrowth into porous polyethylene orbital implants, using serial gadolinium (Gd)‐enhanced magnetic resonance imaging (MRI).Methods: 40 rabbits were divided into two groups, according to the surgical techniques used. Group 1 underwent enucleation of one eye and Medpor implantation, group 2 underwent evisceration and Medpor implantation. All subjects from each group were examined via MRI, and the implants were assessed histologically on the first, second, fourth and eighth postoperative weeks. The degree to which fibrovascular ingrowth occurred was then assessed by measuring the Gd‐enhanced portion via MRI, as well as by histologic examination.Results: There was a significant correlation between the enhanced area on MRI and the fibrovascularized area observed upon histological examination in the two study groups (group 1: r = 0.850 P < 0.001, group 2: r = 0.788, P < 0.001). The area enhanced on MRI was 2.70% smaller in mean value than the fibrovascularized area observed upon histological examination. There was no differences in fibrovascular ingrowth between group 1 and 2. It was also found that there was no differences between the two groups with regard to the enhanced areas on MRI.Conclusion: Gd‐enhanced MRI study proved to be an excellent method for the assessment of fibrovascular ingrowth into the Medpor orbital implants, after both enucleation and evisceration.Keywords
This publication has 22 references indexed in Scilit:
- Different fibrovascularization rate between coralline hydroxyapatite and high density porous polyethylene (Medpore) measured by 99mTc-MDP bone scintigraphy 6 months after intraorbital implantationNuclear Medicine Communications, 2003
- Postcontrast magnetic resonance imaging assessment of porous polyethylene orbital implant (medpor)11The authors have no proprietary interest in any of the materials used in this study.Ophthalmology, 2000
- Magnetic Resonance Imaging versus Bone Scan for Assessment of Vascularization of the Hydroxyapatite Orbital ImplantOphthalmic Plastic & Reconstructive Surgery, 1996
- Histological and Radiological Analyses of Hydroxyapatite Orbital Implants in RabbitsOphthalmic Plastic & Reconstructive Surgery, 1995
- Animal Model of Porous Polyethylene Orbital ImplantsOphthalmic Plastic & Reconstructive Surgery, 1994
- Comparison of Fibrovascular Ingrowth into Hydroxyapatite and Porous Polyethylene Orbital ImplantsOphthalmic Plastic & Reconstructive Surgery, 1994
- Variability of Mineral Density in Coralline Hydroxyapatite SpheresOphthalmic Plastic & Reconstructive Surgery, 1993
- Evaluation of vascularization of coralline hydroxyapatite ocular implants by magnetic resonance imagingClinical Imaging, 1992
- Evolution and Current Concepts in the Surgical Treatment of the Anophthalmic OrbitOphthalmic Plastic & Reconstructive Surgery, 1986
- The Evolution of the Ocular Motility ImplantInternational Ophthalmology Clinics, 1970