Combined high-speed holographic shape and full-field displacement measurements of tympanic membrane
Authors:
Open Access
- 25 September 2018
- journal article
- research article
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 24 (03) , 031008-12
Abstract
The conical shape of the tympanic membrane (TM or eardrum) plays an important role in its function, such that variations in shape alter the acoustically induced motions of the TM. We present a method that precisely determines both shape and acoustically induced transient response of the entire TM using the same optics and maintaining the same coordinate system, where the TM transient displacements due to a broadband acoustic click excitation (50-μs impulse) and the shape are consecutively measured within 2 kHz) optical phase sampling during a single 100-ms wavelength tuning ramp allow precise and rapid reconstructions of the TM shape at varied resolutions (50 to 200 μm). This rapid acquisition of full-field displacements and shape is immune to slow disturbances introduced by breathing or heartbeat of live subjects. Knowledge of TM shape and displacements enables the estimation of surface normal displacements regardless of the orientation of the TM within the measurement system. The proposed method helps better define TM mechanics and provides TM structure and function information useful for the diagnosis of ear disease.Keywords
Funding Information
- Massachusetts Eye and Ear
- National Institute on Deafness and Other Communication Disorders (R01DC016079)
- National Science Foundation (NSF) - Major Research Instrumentation (CMMI-1428921)
This publication has 40 references indexed in Scilit:
- Tympanic membrane contour measurement with two source positions in digital holographic interferometryBiomedical Optics Express, 2012
- Biomechanics of the tympanic membraneJournal of Biomechanics, 2011
- Motion of the surface of the human tympanic membrane measured with stroboscopic holographyHearing Research, 2010
- Motion of the tympanic membrane after cartilage tympanoplasty determined by stroboscopic holographyHearing Research, 2010
- Computer-assisted time-averaged holograms of the motion of the surface of the mammalian tympanic membrane with sound stimuli of 0.4–25kHzHearing Research, 2009
- Optoelectronic holographic otoscope for measurement of nano-displacements in tympanic membranesJournal of Biomedical Optics, 2009
- Investigation of the Mechanics of Type III Stapes Columella Tympanoplasty Using Laser-Doppler VibrometryOtology & Neurotology, 2007
- The discordant eardrumProceedings of the National Academy of Sciences, 2006
- Modeling of the cat eardrum as a thin shell using the finite-element methodThe Journal of the Acoustical Society of America, 1978
- Human Tympanic MembraneActa Oto-Laryngologica, 1970