A biomechanical evaluation of proximal femoral nail antirotation with respect to helical blade position in femoral head: A cadaveric study
Authors:
Open Access
- 1 December 2012
- journal article
- research article
- Published by Springer Nature in Indian Journal of Orthopaedics
- Vol. 46 (6) , 627-632
Abstract
Objective: Despite new developments in the management of osteoporotic fractures, complications like screw cutout are still found in the fixation of proximal femur fractures even with biomechanically proven better implants like proximal femoral nail antirotation (PFNA). The purpose of this cadaveric study was to investigate the biomechanical stability of this device in relation to two common positions (center-center and inferior-center) of the helical blade in the femoral head in unstable trochanteric fractures. Materials and Methods: Eight pairs of human cadaveric femurs were used; in one group [center-center (C-C) group], the helical blade of PFNA was fixed randomly in central position both in anteroposterior and lateral view, whereas in the other group it was fixed in inferior one-third position in anteroposterior and in central position in lateral view [inferior-center (I-C) group]. Unstable intertrochanteric fracture was created and each specimen was loaded cyclically till load to failure Results: Angular and rotational displacements were significantly higher within the C-C group compared to the I-C group in both unloaded and loaded condition. Loading to failure was higher in the I-C group compared to the C-C group. No statistical significance was found for this parameter. Correlations between tip apex distance, cyclic loading which lead to femoral head displacement, and ultimate load to failure showed a significant positive relationship. Conclusion: The I-C group was superior to the C-C group and provided better biomechanical stability for angular and rotational displacement. This study would be a stimulus for further experimental studies with larger number specimens and complex loading protocols at multicentres.Keywords
This publication has 38 references indexed in Scilit:
- Incidence and Economic Burden of Osteoporosis-Related Fractures in the United States, 2005–2025Journal of Bone and Mineral Research, 2007
- Fixation of Revision Implants Is Improved by a Surgical Technique to Crack the Sclerotic Bone rimClinical Orthopaedics and Related Research, 2005
- Dynamic Hip Screw With Trochanteric Stabilizing Plate in the Treatment of Unstable Proximal Femoral Fractures: A Comparative Study With the Gamma Nail and Compression Hip ScrewJournal of Orthopaedic Trauma, 1998
- Biomechanical Analysis of Location of Lag Screw of a Dynamic Hip Screw in Treatment of Unstable Intertrochanteric FractureThe Journal of Trauma: Injury, Infection, and Critical Care, 1996
- Fractured Gamma nailInjury, 1994
- Application of the Joint Coordinate System to Three-Dimensional Joint Attitude and Movement Representation: A Standardization ProposalJournal of Biomechanical Engineering, 1993
- Healing Complications After Internal Fixation of Trochanteric Hip Fractures: The Prognostic Value of OsteoporosisJournal of Orthopaedic Trauma, 1993
- Trochanteric FracturesClinical Orthopaedics and Related Research, 1990
- Torsion and bending analysis of internal fixation techniques for femoral neck fractures: The role of implant design and bone densityJournal of Orthopaedic Research, 1987
- A Clinical and Biomechanical StudyClinical Orthopaedics and Related Research, 1980