Innovative Free-Range Resonant Electrical Energy Delivery System (FREE-D System) for a Ventricular Assist Device Using Wireless Power
Authors:
- 1 January 2014
- journal article
- biomedical engineering
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 60 (1) , 31-37
Abstract
Technological innovation of a smaller, single moving part has an advantage over earlier large pulsatile ventricular assist devices (VADs) prone to mechanical failure. Drivelines limit the potential for extended patient survival durations with newer pumps and act as source for infection, increased morbidity, rehospitalizations, and reduced quality of life. The Free-range Resonant Electrical Energy Delivery (FREE-D) wireless power system uses magnetically coupled resonators to efficiently transfer power. We demonstrate the efficiency over distance of this system. The experimental setup consists of an radiofrequency amplifier and control board which drives the transmit resonator coil, and a receiver unit consisting of a resonant coil attached to a radiofrequency rectifier and power management module. The power management module supplies power to the axial pump, which was set at 9,600 rpm. To achieve a seamless wireless delivery in any room size, we introduced a third relay coil. This relay coil can be installed throughout a room, whereas a single relay coil could be built into a jacket worn by the patient, which would always be within range of the receive coil implanted in the patient’s body. The power was delivered over a meter distance without interruptions or fluctuations with coil, rectifier, and regulator efficiency more than 80% and overall system efficiency of 61%. The axial pump worked well throughout the 8 hours of continuous operation. Having same setup on the opposite side can double the distance. A tether-free operation of a VAD can be achieved by FREE-D system in room-size distances. It has the potential to make the VAD therapy more acceptable from the patient perspective.Keywords
This publication has 13 references indexed in Scilit:
- Powering a Ventricular Assist Device (VAD) With the Free-Range Resonant Electrical Energy Delivery (FREE-D) SystemProceedings of the IEEE, 2011
- Analysis, Experimental Results, and Range Adaptation of Magnetically Coupled Resonators for Wireless Power TransferIEEE Transactions on Industrial Electronics, 2010
- Obesity and Left Ventricular Assist Device Driveline Exit Site InfectionASAIO Journal, 2010
- Advanced Heart Failure Treated with Continuous-Flow Left Ventricular Assist DeviceNew England Journal of Medicine, 2009
- Extended Mechanical Circulatory Support With a Continuous-Flow Rotary Left Ventricular Assist DeviceJACC, 2009
- Efficient wireless non-radiative mid-range energy transferAnnals of Physics, 2008
- Use of a Continuous-Flow Device in Patients Awaiting Heart TransplantationNew England Journal of Medicine, 2007
- Late-Onset Driveline Infections: The Achilles’ Heel of Prolonged Left Ventricular Assist Device SupportThe Annals of Thoracic Surgery, 2007
- Infections associated with ventricular assist devices: epidemiology and effect on prognosis after transplantationTransplant Infectious Disease, 2007
- Ventricular assist device-related infectionsThe Lancet Infectious Diseases, 2006