Backward flow in a surface tension driven micropump

Authors:
  • JJJongil Ju
    Jongil Ju
  • JPJoong Yull Park
    Joong Yull Park
  • KKKyung Chun Kim
    Kyung Chun Kim
  • HKHyundong Kim
    Hyundong Kim
  • EBErwin Berthier
    Erwin Berthier
  • DBDavid J Beebe
    David J Beebe
  • SLSang-Hoon Lee
    Sang-Hoon Lee

Abstract
A surface tension driven micropump harnessing the pressure difference generated by drops of different curvature radii proves to be a simple and attractive passive method to drive fluid flow in microdevices. Here we observed the appearance of backward flow when the initial sizes of the droplets at the inlet and outlet ports are similar. To explain this phenomenon several hypotheses have been investigated. Consideration of the inertia of the fluid in the channel revealed that it alone is insufficient to explain the observed backward flow. We discovered that rotational flow inside the outlet droplet could be a source of inertia, explaining the generation of the backward flow. In addition, we have experimentally determined that the ratio of the volumes of the initial outlet drop and inlet drop correlates with the occurrence of the backward flow.

This publication has 13 references indexed in Scilit: