Paper 10: Radial Forces in Centrifugal Pumps with Guide Vanes
Authors:
- 1 September 1969
- journal article
- research article
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Conference Proceedings
- Vol. 184 (14) , 101-107
Abstract
At partial and overload conditions, radial decentralizing forces act upon the rotor of a centrifugal pump with guide vanes if the impeller is out of centre. The magnitude of these forces depends on load conditions, and the forces increase with growing eccentricity. At very small flow, these forces become non-stationary. They rotate at a considerably lower frequency than the velocity frequency and may lead to rotor vibrations. The paper discusses the effects of stationary and non-stationary radial forces, and resulting shaft deflections and vibrations, from measurements on two experimental test rigs. The paper also presents the results of research on the pressure distribution of guide vanes, carried out in air, and gives observations of flow patterns in a shallow water test rig.Keywords
This publication has 6 references indexed in Scilit:
- Radial Force on the Impeller of Centrifugal Pumps With Volute, Semivolute, and Fully Concentric CasingsJournal of Engineering for Power, 1965
- Radial Forces in a Pump Impeller Caused by a Volute CasingJournal of Engineering for Power, 1962
- Die Kreiselpumpen für Flüssigkeiten und Gase1961
- Volute Pressure Distribution, Radial Force on the Impeller, and Volute Mixing Losses of a Radial Flow Centrifugal PumpJournal of Engineering for Power, 1960
- An Experimental Investigation of Radial Thrust in Centrifugal PumpsJournal of Engineering for Power, 1960
- Turbinen und Pumpen1932