Optimization of the Spot Spacings for Reducing Roughness in Laser-Induced Optical Breakdown Processes for Corneal Laser Vision Correction
Open Access
Abstract
The aim of this work is to implement an algorithm that simulates a simplified cutting surface based on laser-induced optical breakdown (LIOB). The algorithm includes the definition of a possible positioning of the laser pulses and calculation of the roughness for different parameter settings (including LIOB threshold, pulse energies, and spot spacings) as the difference between simulated and ideal target cut (local differences within the cut, i.e., the waviness of the simulated cut vs. the homogeneity of the ideal target cut). Furthermore, optimizations of specific variables, such as spot distance (along the pathway), track distance (between lines/tracks), and pulse energy, are performed. The simulations suggest that lower pulse energies (well above the LIOB threshold) combined with asymmetric spacings (spot-to-track distance ratio >> 1) may be effective to lower the roughness of laser cuts generated by LIOB processes. The importance of lowering pulse energies (well above the threshold) emphasizes the need for the LIOB threshold to remain low (as low as possible). Reducing roughness by decreasing spacings (thus, increasing dose for same pulse energies) may have negative implications in visual recovery (risk for overdose). In all cases, the roughness is multiple times larger (rougher) than equivalent simulations for ablative procedures.Keywords
This publication has 21 references indexed in Scilit:
- RETRACTED: Effect of Lowering Laser Energy on the Surface Roughness of Human Corneal Lenticules in SMILEJournal of Refractive Surgery, 2017
- Lower Laser Energy Levels Lead to Better Visual Recovery After Small-Incision Lenticule Extraction: Prospective Randomized Clinical TrialAmerican Journal of Ophthalmology, 2017
- Optimum Laser Beam Characteristics for Achieving Smoother Ablations in Laser Vision CorrectionInvestigative Ophthalmology & Visual Science, 2017
- Advanced Surface Ablation With a New Software for the Reduction of Ablation IrregularitiesJournal of Refractive Surgery, 2017
- Trans advanced surface laser ablation (TransPRK) outcomes using SmartPulseTechnologyContact Lens and Anterior Eye, 2017
- Lower Energy Levels Improve Visual Recovery in Small Incision Lenticule Extraction (SMILE)Journal of Refractive Surgery, 2016
- Optical side-effects of fs-laser treatment in refractive surgery investigated by means of a model eyeBiomedical Optics Express, 2013
- Surface Quality of Femtosecond Dissected Posterior Human Corneal Stroma Investigated With Atomic Force MicroscopyCornea, 2012
- Ablation Resolution in Laser Corneal Refractive Surgery: The Dual Fluence Concept of the AMARIS PlatformAdvances in Optical Technologies, 2010
- Compressed sensingIEEE Transactions on Information Theory, 2006