Evaluation of Tear Film Interference Patterns and Measures of Tear Break-Up Time
Authors:
- Jason J. NicholsJNJason J. Nichols
- Kelly K. NicholsKNKelly K. Nichols
- Brian PuentBPBrian Puent
- Mario SaracinoMSMario Saracino
- G. Lynn MitchellGMG. Lynn Mitchell
- 1 June 2002
- journal article
- research article
- Published by Wiley in Optometry and Vision Science
- Vol. 79 (6) , 363-369
Abstract
The purpose of this study was to compare the agreement within and between examiners when evaluating real-time and digital photographs of TearScope Plus tear film interference patterns. We also evaluated between-examiner agreement of noninvasive digital tear break-up time (NITBUT) using the TearScope, the relation between NITBUT and tear film interference patterns, and the relation between NITBUT and tear break-up time (TBUT). Forty nondry eye patients were seen for digital imaging of the tear film using the TearScope Plus mounted on a slit-lamp with the EyeCap Ophthalmic Image Capture System. Two independent examiners first assessed the tear interference pattern in real-time and then captured the patterns and NITBUT digitally for a period of approximately 60 s. Each image series was later graded for interference pattern and NITBUT by the two independent, masked examiners. Within-examiner comparisons of real-time and digital tear pattern photograph grading showed moderate to substantial agreement for experienced examiners (kappa for examiner 1 = 0.76 and kappa for examiner 2 = 0.55). Between-examiner agreement when grading tear patterns was also substantial in real-time (kappa = 0.72) and moderate when using digital photography (kappa = 0.59). The between-examiner mean NITBUT was 11.2 ± 6.8 s and the 95% limits of agreement between examiners were −19.2 to +9.2 s. The mean TBUT was 7.6 ± 10.4 s, and it was on average 3.7 ± 12.0 s shorter than NITBUT (p = 0.06). Thicker tear film interference patterns graded photographically were associated with longer NITBUTs for both examiners (p = 0.001). There is moderate to substantial within- and between-examiner agreement when comparing real-time and digital tear interference patterns photographs when using the TearScope. Although there is considerable between-examiner variability with the NITBUT test, the thicker lipid layer tear patterns tend to be associated with longer NITBUTs.Keywords
This publication has 32 references indexed in Scilit:
- Effects of laser in situ keratomileusis on tear production, clearance, and the ocular surfaceOphthalmology, 2001
- Dry eye after laser in situ keratomileusisAmerican Journal of Ophthalmology, 2001
- Decrease in Tear Secretion and Corneal Sensitivity After Laser In Situ KeratomileusisCornea, 2001
- Forecasting of hydrophilic contact lens tolerance by means of tear ferning testGraefe's Archive for Clinical and Experimental Ophthalmology, 1998
- Abnormal Lipid Layers1998
- Preocular Tear Film Characteristics of Nonwearers and Soft Contact Lens WearersOptometry and Vision Science, 1997
- Model for Ocular Tear Film FunctionCornea, 1996
- Hydrogel Lens Water Content and the Stability of the Prelens Tear FilmOptometry and Vision Science, 1991
- Effect of Hydrogel Lens Wear on Tear Film StabilityOptometry and Vision Science, 1991
- Breakup of the Tear FilmInternational Ophthalmology Clinics, 1973