Viewing conditions for diagnostic images in three major Dublin hospitals: a comparison with WHO and CEC recommendations
Authors:
- P C BrennanPBP C Brennan
- 1 February 2003
- journal article
- research article
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 76 (902) , 94-97
Abstract
Accurate interpretation of X-ray images is dependent on image viewing conditions. A recent study in Ireland demonstrated that even with the advent of digital departments the majority of images are still viewed using viewing boxes. This investigation aimed to measure average viewing box brightness, percentage uniformity and ambient light levels in radiology and radiographer viewing areas and wards within three major Dublin hospitals. The results were compared with published recommendations by the World Health Organization and Commission of the European Communities. Following analysis of more than 4650 measurements, it was shown that mean values for average viewing box brightness for all departments failed to achieve recommended levels. Only one third of areas met the most lenient guideline for percentage uniformity. Ambient lighting was shown to be unacceptable for ward areas. For all three parameters, radiology areas generally fared best, with wards gaining the poorest scores. Following a 3 min cleaning regimen of viewing boxes, the average brightness and percentage uniformity were improved in 100% and 80%, respectively, of viewing boxes, but average brightness values remained below recommended levels. The importance of comprehensive quality assurance programmes for viewing boxes has been highlighted so that visualization of images is not reduced to sub-optimal levels. The need for consistent and more informative recommendations has been emphasized.Keywords
This publication has 9 references indexed in Scilit:
- Irish X-ray departments demonstrate varying levels of adherence to European guidelines on good radiographic techniqueBritish Journal of Radiology, 2002
- In the eyes of the beholder: what we see is not what we getBritish Journal of Radiology, 2001
- The influence of viewing conditions on radiological diagnosis of periapical inflammationBritish Dental Journal, 2000
- Reference dose levels for patients undergoing common diagnostic X-ray examinations in Irish hospitals.British Journal of Radiology, 2000
- Influence of film and monitor display luminance on observer performance and visual searchAcademic Radiology, 1999
- Survey of Image Viewing Conditions for X Ray FilmRadiation Protection Dosimetry, 1995
- Increasing contrast when viewing radiographic images.Radiology, 1992
- Quality assurance of viewing boxes: proposal for establishing minimum requirements and results from a Spanish quality control programmeBritish Journal of Radiology, 1990
- The Influence of Ambient and Viewbox Light upon Visual Detection of Low-Contrast Targets in a RadiographInvestigative Radiology, 1982