Fluid dynamics in three 25‐gauge vitrectomy systems: principles for use in vitreoretinal surgery
- 1 March 2008
- journal article
- research article
- Published by Wiley in Acta Ophthalmologica
- Vol. 86 (2) , 156-159
Abstract
: Purpose: To compare infusion and extrusion fluid volumes with three 25‐gauge vitrectomy systems.Methods: The infusion and aspiration rates of 25‐gauge systems from Alcon (Fort Worth, TX, USA), Bausch & Lomb (St Louis, MO, USA), and the Dutch Ophthalmic Research Centre (DORC, Zuidland, the Netherlands) were measured in vitro using balanced saline solution with different heights (40, 60, 80, 100, 120 cm) of infusion bottle, cutter velocities (800, 1100, 1500 cuts/ min) and aspiration powers (100, 200, 300, 400, 500 mmHg).Results: The infusion flow velocities differed among the systems (p < 0.001 for all comparisons [p‐values 0.0009−0.0001]). The aspiration rates of the Alcon and Bausch & Lomb systems were lower than that of the DORC system (p < 0.02 for all comparisons [p‐values 0.018−0.002]).Conclusions: Infusion and extrusion fluid rates differ among 25‐gauge vitrectomy systems. These results may help to optimize ideal aspiration and infusion parameters among 25‐gauge vitrectomy systems used to treat vitreoretinal diseases.Keywords
This publication has 11 references indexed in Scilit:
- AN ENGINEERING APPROACH TO VITREORETINAL SURGERYRetina, 2004
- Long-term alteration in the air-infused rabbit retinaGraefe's Archive for Clinical and Experimental Ophthalmology, 2003
- A new 25-gauge instrument system for transconjunctival sutureless vitrectomy surgery1 1The new Transconjunctival Sutureless Vitrectomy System is disclosed to Bausch and Lomb Surgical, St. Louis, MO. The Microsurgery Advanced Design Laboratory (MADLAB) may receive royalties related to the sale of this and other instruments mentioned in the article.Ophthalmology, 2002
- Initial experience using the transconjunctival sutureless vitrectomy system for vitreoretinal surgery1 1The new Transconjunctival Sutureless Vitrectomy System is disclosed to Bausch & Lomb Surgical, St. Louis, MO. The Microsurgery Advanced Design Laboratory (MADLAB) may receive royalties related to the sale of this and other instruments mentioned in the article.Ophthalmology, 2002
- Evaluation of retinal damage induced by air/fluid exchange using a trypan blue inclusion test in rabbitsAmerican Journal of Ophthalmology, 2001
- Effect of infusion air pressure on visual field defects after macular hole surgeryAmerican Journal of Ophthalmology, 2000
- Modified sutureless sclerotomies in pars plana vitrectomyAmerican Journal of Ophthalmology, 2000
- Modified sutureless sclerotomies in pars plana vitrectomyAmerican Journal of Ophthalmology, 1999
- Sutureless Pars Plana Vitrectomy Through Self-sealing SclerotomiesArchives of Ophthalmology (1950), 1996
- Refinements in Microinstrumentation for Vitreous SurgeryAmerican Journal of Ophthalmology, 1990