Risk of Recall Among Plastic Surgery Devices Cleared Through the FDA 510(k) Pathway
Authors:
- Ravi DhawanRDRavi Dhawan
- Alexandra BoricABAlexandra Boric
- Orr ShaulyOSOrr Shauly
- Troy MarxenTMTroy Marxen
- Anjali OmAOAnjali Om
- Kendall BrooksKBKendall Brooks
- Gabriela García NoresGNGabriela García Nores
- Albert LoskenALAlbert Losken
Open Access
- 14 January 2026
- journal article
- Published by Oxford University Press (OUP) in Aesthetic Surgery Journal Open Forum
- Vol. 8, ojag126
Abstract
Background: The FDA 510(k) pathway is the predominant route by which medical devices reach the US market. Previous studies have examined recall risk across broad FDA panels, but none have characterized plastic surgery devices or compared recall patterns across subcategories within the field. Objectives: The aim of this study was to determine the rate and severity of FDA recalls among 510(k)-cleared plastic surgery devices, compare recall risk across subcategories, and benchmark against all other 510(k) devices. Methods: All 510(k)-cleared devices (2008-2023) were obtained from the FDA premarket notification database. Two reviewers classified 234 surgery panel product codes, identifying 103 plastic surgery codes (3194 devices) in 8 subcategories. Each device was matched to the FDA recall database by its 510(k) number. All remaining 510(k) devices (n = 45,182) served as comparator. Recall rates were compared using χ2 tests and risk ratios (RR); time to first recall was modeled with Cox proportional hazards regression with Bonferroni correction. Results: Of 3194 plastic surgery devices, 197 (6.2%) were recalled, including 11 Class I recalls (0.3%). The recall rate for all other 510(k) devices was 11.4% (RR, 0.54; 95% CI, 0.47-0.62; P < .001). After Bonferroni correction, 4 subcategories had elevated recall hazard vs lasers and energy: implants and fixation (hazard ratio [HR], 3.64), negative pressure wound therapy (HR, 2.53), surgical mesh and acellular dermal matrices (HR, 2.46), and wound closure (HR, 2.01). Conclusions: Plastic surgery 510(k) devices had a lower recall rate than nonplastic surgery devices, although risk varied substantially across subcategories. These data provide a specialty-specific baseline for postmarket device surveillance. Level of Evidence: 5 (Therapeutic): For image description, please refer to the figure legend and surrounding text.Keywords
This publication has 36 references indexed in Scilit:
- The regulatory ancestral network of surgical meshesPLOS ONE, 2018
- Transparency and Dermatologic Device Approval by the US Food and Drug AdministrationJAMA Dermatology, 2018
- Analysis of FDA-Approved Orthopaedic Devices and Their RecallsJournal of Bone and Joint Surgery, 2016
- Characteristics of Clinical Studies Conducted Over the Total Product Life Cycle of High-Risk Therapeutic Medical Devices Receiving FDA Premarket Approval in 2010 and 2011JAMA, 2015
- Multicenter Prospective Cohort Study of the Incidence of Adverse Events Associated With Cosmetic Dermatologic ProceduresJAMA Dermatology, 2015
- Lack of Publicly Available Scientific Evidence on the Safety and Effectiveness of Implanted Medical DevicesJAMA Internal Medicine, 2014
- Assessment of Cardiovascular and Noncardiovascular Medical Device RecallsThe American Journal of Cardiology, 2014
- Complications in Cosmetic Laser Surgery: A Review of 494 Food and Drug Administration Manufacturer and User Facility Device Experience ReportsDermatologic Surgery, 2014
- A Paradigm Shift in U.S. Breast ReconstructionPlastic and Reconstructive Surgery, 2013
- Medical Device Recalls and the FDA Approval ProcessArchives of internal medicine (1960), 2011