Transcatheter aortic valve implantation in patients with a small aortic annulus: performance of supra-, intra- and infra-annular transcatheter heart valves
Authors:
Open Access
- 13 August 2021
- journal article
- research article
- Published by Springer Nature in Clinical Research in Cardiology
- Vol. 110 (12) , 1957-1966
Abstract
Background: A small aortic annulus is associated with increased risk of prosthesis–patient mismatch (PPM) after transcatheter aortic valve implantation (TAVI). Whether specific transcatheter heart valve (THV) designs yield superior hemodynamic performance in these small anatomies remains unclear. Methods: Data from 8411 consecutive patients treated with TAVI from May 2012 to April 2019 at four German centers were retrospectively evaluated. A small aortic annulus was defined as multidetector computed tomography-derived annulus area < 400 mm2. TAVI was performed with a balloon-expanding intra-annular (Sapien-3, n = 288), self-expanding intra-annular (Portico, n = 110), self-expanding supra-annular (Evolut, n = 179 and Acurate-Neo, n = 428) and mechanically expanding infra-annular (Lotus, n = 64) THV according to local practice. PPM was defined as indexed effective orifice area ≤ 0.85cm2/m2. Results: A small annulus was found in 1069 (12.7%) patients. PPM was detected in 38.3% overall with a higher prevalence after implantation of a balloon-expanding intra-annular or mechanically expanding infra-annular THV compared to self-expanding intra- and supra-annular THV. Multivariable analysis linked self-expanding THV (Evolut: Odds ratio [OR] 0.341, Acurate-Neo: OR 0.436, Portico: OR 0.291), postdilatation (OR 0.648) and age (OR 0.968) to lower rates of PPM, while aortic valve calcification was associated with an increased risk (OR 1.001). Paravalvular regurgitation > mild was more frequent after TAVI with self-expanding THV (p = 0.04). Conclusion: In this large contemporary multicenter patient population, a substantial number of patients with a small aortic anatomy were left with PPM after TAVI. Self-expanding supra- and intra-annular THV demonstrated superior hemodynamics in these patients at risk, however at the cost of higher rates of residual paravalvular regurgitation. GraphicKeywords
Funding Information
- Universitätsklinikum Hamburg-Eppendorf (UKE)
This publication has 21 references indexed in Scilit:
- Transcatheter aortic valve replacement with Evolut R versus Sapien 3 in Japanese patients with a small aortic annulus: The OCEAN‐TAVI registryCatheterization and Cardiovascular Interventions, 2020
- Transcatheter Self-Expandable Valve Implantation for Aortic Stenosis in Small Aortic AnnuliJACC: Cardiovascular Interventions, 2020
- Aortic Root Enlargement Is Safe and Reduces the Incidence of Patient-Prosthesis Mismatch: A Meta-analysis of Early and Late OutcomesCanadian Journal of Cardiology, 2019
- Prosthesis–Patient Mismatch in Patients Undergoing Transcatheter Aortic Valve ReplacementJACC, 2018
- Incidence and impact of prosthesis–patient mismatch following transcatheter aortic valve implantationClinical Research in Cardiology, 2018
- Short-Term Outcome and Hemodynamic Performance of Next-Generation Self-Expanding Versus Balloon-Expandable Transcatheter Aortic Valves in Patients With Small Aortic AnnulusCirculation: Cardiovascular Interventions, 2017
- Predictors and Outcomes of Prosthesis-Patient Mismatch After Aortic Valve ReplacementJACC: Cardiovascular Imaging, 2016
- Sutureless Versus Stented Valve in Aortic Valve Replacement in Patients With Small AnnulusThe Annals of Thoracic Surgery, 2016
- Prosthesis–Patient Mismatch After Transcatheter Aortic Valve ImplantationThe Annals of Thoracic Surgery, 2016
- Incidence and Sequelae of Prosthesis-Patient Mismatch in Transcatheter Versus Surgical Valve Replacement in High-Risk Patients With Severe Aortic StenosisJACC, 2014