Pulse transit time based respiratory rate estimation with singular spectrum analysis
- 13 December 2019
- journal article
- research article
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 58 (2) , 257-266
Abstract
Respiratory rate (RR) is an important vital sign which can be difficult to measure accurately and unobtrusively in routine clinical practice. Pulse transit time (PTT), on the other hand, is unobtrusive to collect from electrocardiogram (ECG) and photoplethysmogram (PPG) signals. Using PTT is a novel method to estimate and monitor blood pressure (BP) and RR. This study aimed to estimate continuous RR using PTT with singular spectrum analysis to extract respiratory components. The performance of this method was validated on 17 subjects who carried out spontaneous breathing and controlled deep breathing conditions. Three types of estimated RR parameters (average RR by power spectral density (PSD) (RRPSD), number of breaths (RR#), and instantaneous RR (RRinst)) were compared with the corresponding reference RR. The reference RR was collected using a respiratory belt. Our findings demonstrate that the PTT signal reliably tracked respiratory variation with a root mean square error of 0.84, 1.11, and 0.74 breaths/min for RRPSD, RR#, and RRinst estimations, respectively. Overall, RR estimated by PTT was more accurate than heart/pulse rate interval, QRS area, and PPG amplitude, which were also extracted from ECG and PPG. The results suggest that it may be feasible to use PTT as an estimation of RR and that ECG and PPG may be relied upon for monitoring not only RR but also BP and heart rate.Keywords
Funding Information
- External Cooperation Program of the Chinese Academy of Sciences (GJHZ1212)
This publication has 30 references indexed in Scilit:
- Pulse transit time as a measure of respiratory effort under noninvasive ventilationEuropean Respiratory Journal, 2012
- Respiration rate monitoring methods: A reviewPediatric Pulmonology, 2011
- Pulse transit time measured from the ECG: an unreliable marker of beat-to-beat blood pressureJournal of Applied Physiology, 2006
- The vexatious vital: Neither clinical measurements by nurses nor an electronic monitor provides accurate measurements of respiratory rate in triageAnnals of Emergency Medicine, 2005
- Aortic‐Radial Pulse Transit Time and ECG Q‐Wave to Radial Pulse Wave Interval as Indices of Beat‐By‐Beat Blood Pressure ChangePsychophysiology, 1983
- Pulse Transit Time as an Indicator of Arterial Blood PressurePsychophysiology, 1981
- Pulse Transit Time: Relationship to Blood Pressure and Myocardial PerformancePsychophysiology, 1979
- THE EFFECT OF BLOOD PRESSURE ALTERATION ON THE PULSE WAVE VELOCITYHeart, 1964
- Interrelationships of Cardiac Output, Blood Pressure, and Peripheral Resistance during Normal Respiration in Normotensive and Hypertensive IndividualsCirculation, 1951
- The variation of arterial elasticity with blood pressure in man (Part I)Proceedings of the Royal Society of London. Series B, Containing Papers of a Biological Character, 1923