Comparison of genome-wide array genomic hybridization platforms for the detection of copy number variants in idiopathic mental retardation
Authors:
- Tracy TuckerTTTracy Tucker
- Alexandre MontpetitAMAlexandre Montpetit
- David ChaiDCDavid Chai
- Susanna ChanSCSusanna Chan
- Sébastien ChénierSCSébastien Chénier
- Bradley P CoeBCBradley P Coe
- Allen DelaneyADAllen Delaney
- Patrice EydouxPEPatrice Eydoux
- Wan L LamWLWan L Lam
- Sylvie LangloisSLSylvie Langlois
- Emmanuelle LemyreELEmmanuelle Lemyre
- Marco MarraMMMarco Marra
Open Access
- 25 March 2011
- journal article
- research article
- Published by Springer Nature in BMC Medical Genomics
- Vol. 4 (1) , 25
Abstract
Clinical laboratories are adopting array genomic hybridization as a standard clinical test. A number of whole genome array genomic hybridization platforms are available, but little is known about their comparative performance in a clinical context. We studied 30 children with idiopathic MR and both unaffected parents of each child using Affymetrix 500 K GeneChip SNP arrays, Agilent Human Genome 244 K oligonucleotide arrays and NimbleGen 385 K Whole-Genome oligonucleotide arrays. We also determined whether CNVs called on these platforms were detected by Illumina Hap550 beadchips or SMRT 32 K BAC whole genome tiling arrays and tested 15 of the 30 trios on Affymetrix 6.0 SNP arrays. The Affymetrix 500 K, Agilent and NimbleGen platforms identified 3061 autosomal and 117 X chromosomal CNVs in the 30 trios. 147 of these CNVs appeared to be de novo, but only 34 (22%) were found on more than one platform. Performing genotype-phenotype correlations, we identified 7 most likely pathogenic and 2 possibly pathogenic CNVs for MR. All 9 of these putatively pathogenic CNVs were detected by the Affymetrix 500 K, Agilent, NimbleGen and the Illumina arrays, and 5 were found by the SMRT BAC array. Both putatively pathogenic CNVs identified in the 15 trios tested with the Affymetrix 6.0 were identified by this platform. Our findings demonstrate that different results are obtained with different platforms and illustrate the trade-off that exists between sensitivity and specificity. The large number of apparently false positive CNV calls on each of the platforms supports the need for validating clinically important findings with a different technology.Keywords
This publication has 50 references indexed in Scilit:
- Intersectin Regulates Dendritic Spine Development and Somatodendritic Endocytosis but Not Synaptic Vesicle Recycling in Hippocampal NeuronsJournal of Biological Chemistry, 2009
- Recurrent reciprocal 1q21.1 deletions and duplications associated with microcephaly or macrocephaly and developmental and behavioral abnormalitiesNature Genetics, 2008
- The diploid genome sequence of an Asian individualNature, 2008
- X-linked protocadherin 19 mutations cause female-limited epilepsy and cognitive impairmentNature Genetics, 2008
- Mapping and sequencing of structural variation from eight human genomesNature, 2008
- The complete genome of an individual by massively parallel DNA sequencingNature, 2008
- Methods and strategies for analyzing copy number variation using DNA microarraysNature Genetics, 2007
- Genome-wide Copy Number Profiling on High-density Bacterial Artificial Chromosomes, Single-nucleotide Polymorphisms, and Oligonucleotide Microarrays: A Platform Comparison based on Statistical Power AnalysisDNA Research, 2007
- Global variation in copy number in the human genomeNature, 2006
- Cloning, expression analysis, and chromosomal localization of a novel butyrophilin-like receptorJournal of Human Genetics, 1999