The effect of extremely narrow MLC leaf width on the plan quality of VMAT for prostate cancer
Open Access
- 23 June 2016
- journal article
- research article
- Published by Springer Nature in Radiation Oncology
- Vol. 11 (1) , 1-9
Abstract
To investigate the effect of multi-leaf collimators (MLCs) with leaf width of 1.25 mm on the plan quality of volumetric modulated arc therapy (VMAT) for prostate cancer. A total of 20 patients with prostate cancer were retrospectively selected. Using a high definition MLC (HD MLC), primary and boost VMAT plans with two full arcs were generated for each patient (original plan). After that, by shifting the isocenter position of the 2nd arc by 1.25 mm in the cranio-caudal direction, we simulated fluences made with MLCs with leaf width of 1.25 mm. After shifting, primary and boost plans were generated for each patient (shifted plan). A sum plan was generated by summation of the primary and boost plan for each patient. Dose-volumetric parameters were calculated and compared. Both the homogeneity index (HI) and conformity index (CI) of the shifted plans were better than those of the original plans in primary plans (HI = 0.065 vs. 0.059 with p < 0.001 and CI = 1.056 vs. 1.044 with p = 0.006). Similarly, the shifted plans for the boost target volume showed better homogeneity and conformity than did the original plans (HI = 0.060 vs. 0.053 with p < 0.001 and CI = 1.015 vs. 1.009 with p < 0.001). The target mean dose of the original plans was closer to the prescription dose than that of the shifted plans in the case of sum plans (81.45 Gy vs. 81.12 Gy with p = 0.001). Use of extremely narrow MLCs could increase dose homogeneity and conformity of the target volume for prostate VMAT.Keywords
Funding Information
- National Research Foundation of Korea (2015R1C1A1A02036331)
This publication has 18 references indexed in Scilit:
- Increasing the number of arcs improves head and neck volumetric modulated arc therapy plansActa Oncologica, 2014
- Dosimetric effects of multileaf collimator leaf width on intensity‐modulated radiotherapy for head and neck cancerMedical Physics, 2014
- A Comparison Study of Volumetric Modulated Arc Therapy Quality Assurances Using Portal Dosimetry and MapCHECK 2Progress in Medical Physics, 2014
- A predictive model to guide management of the overlap region between target volume and organs at risk in prostate cancer volumetric modulated arc therapyRadiation Oncology Journal, 2014
- Effect of MLC leaf width on treatment adaptation and accuracy for concurrent irradiation of prostate and pelvic lymph nodesMedical Physics, 2013
- RapidArc®vsintensity-modulated radiation therapy for hepatocellular carcinoma: a comparative planning studyBritish Journal of Radiology, 2012
- Photon energy-modulated radiotherapy: Monte Carlo simulation and treatment planning studyMedical Physics, 2012
- Influence of MLC leaf width on biologically adapted IMRT plansActa Oncologica, 2010
- Prescribing, Recording, and Reporting Photon-Beam Intensity-Modulated Radiation Therapy (IMRT):Journal of the ICRU, 2010
- Volumetric modulated arc therapy: IMRT in a single gantry arcMedical Physics, 2007