A simple, rapid and sensitive method based on modified multiwalled carbon nanotube for preconcentration and determination of lead ions in aqueous media in natural pHs
Open Access
- 18 November 2014
- journal article
- research article
- Published by Scientific Scholar in Arabian Journal of Chemistry
- Vol. 12 (7) , 1315-1321
Abstract
In this study, multiwalled carbon nanotube (MWCNT) was modified by the pyridine group using a silane agent and characterized by infrared spectroscopy (IR), thermal analysis (TG/DTA), and elemental analysis (CHN) and scanning electron microscopy (SEM). The application of this sorbent was investigated in determination of lead ions in aqueous samples, using flame atomic absorption spectrometry (FAAS). Through this study, different parameters such as pH and sample flow rate on adsorption process and eluent concentration, volume and flow rate were optimized. The limit of detection (LOD), the relative standard deviation and the recovery of the method were 2 ng mL−1, 1.3% and 99.7%, respectively. Two standard reference materials (NIST 1571 and NIST 1572) were used to verify accuracy of this method. Finally, the sorbent was successfully applied for extraction and determination of low levels of Pb(II) ions in aqueous samples.Keywords
This publication has 22 references indexed in Scilit:
- Novel ion imprinted polymer coated multiwalled carbon nanotubes as a high selective sorbent for determination of gold ions in environmental samplesChemical Engineering Journal, 2013
- Novel magnetic ion imprinted polymer as a highly selective sorbent for extraction of gold ions in aqueous samplesAnalytical Methods, 2012
- The Solid Phase Extraction of Lead Using Silver Nanoparticles – Attached to Silica Gel Prior to its Determination by FAASCurrent Analytical Chemistry, 2009
- Preconcentration of some trace elements via using multiwalled carbon nanotubes as solid phase extraction adsorbentJournal of Hazardous Materials, 2009
- Surface modification of multi-walled carbon nanotubes using 3-aminopropyltriethoxysilaneJournal of Materials Science, 2007
- Atomic spectrometry update. Advances in atomic emission, absorption and fluorescence spectrometry and related techniquesJournal of Analytical Atomic Spectrometry, 2004
- Cork biomass as biosorbent for Cu(II), Zn(II) and Ni(II)Colloids and Surfaces A: Physicochemical and Engineering Aspects, 2003
- Determination of lead in oil products by derivative potentiometric stripping analysisAnalytica Chimica Acta, 1999
- Lead poisoning and brain cell function.Environmental Health Perspectives, 1990
- Lead exposure and neurobehavioral development in later infancy.Environmental Health Perspectives, 1990