18F-FDG PET/CT in the diagnosis of prosthetic valve endocarditis
Authors:
- 26 November 2015
- journal article
- research article
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 32 (4) , 679-686
Abstract
Recent studies have shown promising results using 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) in the diagnosis of prosthetic valve endocarditis (PVE). However, previous studies did not include negative controls. The aim of this study was to compare 18F-FDG-uptake around prosthetic aortic valves in patients with and without PVE and to determine the diagnostic performance of 18F-FDG PET/CT in the diagnosis of PVE. 18F-FDG PET/CT examinations in patients with a prosthetic aortic valve performed 2008–2014 were retrieved. Eight patients with a final diagnosis of definite PVE were included in the analysis of the diagnostic performance of 18F-FDG PET/CT. Examinations performed on suspicion of malignancy in patients without PVE (n = 19) were used as negative controls. Visual and semi-quantitative analysis was performed. Maximal standardized uptake value (SUVmax) in the valve area was measured and SUVratio was calculated by dividing valve SUVmax by SUVmax in the descending aorta. The sensitivity was 75 %, specificity 84 %, positive likelihood ratio [LR(+)] 4.8 and negative likelihood ratio [LR(−)] 0.3 on visual analysis. Both SUVmax and SUVratio were significantly higher in PVE patients [5.8 (IQR 3.5–6.5) and 2.4 (IQR 1.7–3.0)] compared to non-PVE patients [3.2 (IQR 2.8–3.8) and 1.5 (IQR 1.3–1.6)] (p < 0.001). ROC-curve analysis of SUVratio yielded an area under the curve of 0.90 (95 % CI 0.74–1.0). 18F-FDG-uptake around non-infected aortic prosthetic valves was low. The level of 18F-FDG-uptake in the prosthetic valve area showed a good diagnostic performance in the diagnosis of PVE.Keywords
This publication has 18 references indexed in Scilit:
- Improving the Diagnosis of Infective Endocarditis in Prosthetic Valves and Intracardiac Devices With 18 F-Fluordeoxyglucose Positron Emission Tomography/Computed Tomography AngiographyCirculation, 2015
- 18-Fluoro-2-deoxyglucose positron emission tomography–computed tomography: an additional tool in the diagnosis of prosthetic valve endocarditisInternational Journal of Infectious Diseases, 2014
- Positron Emission Tomography/Computed Tomography for Diagnosis of Prosthetic Valve EndocarditisJACC, 2014
- EANM/SNMMI Guideline for18F-FDG Use in Inflammation and InfectionJournal of Nuclear Medicine, 2013
- A Systematic Review of the Factors Affecting Accuracy of SUV MeasurementsAmerican Journal of Roentgenology, 2010
- Recommendations for the practice of echocardiography in infective endocarditisEuropean Heart Journal - Cardiovascular Imaging, 2010
- Recommendations for Evaluation of Prosthetic Valves With Echocardiography and Doppler UltrasoundJournal of the American Society of Echocardiography, 2009
- Abscess in infective endocarditis: The value of transesophageal echocardiography and outcomeAmerican Heart Journal, 2007
- Proposed Modifications to the Duke Criteria for the Diagnosis of Infective EndocarditisClinical Infectious Diseases, 2000
- The stentless Toronto SPV bioprosthesis for aortic valve replacementCardiovascular Surgery, 1996