Theory and Experiments of Transport at Channel Microband Electrodes Under Laminar Flow. 3. Electrochemical Detection at Electrode Arrays under Steady State
- 25 February 2010
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 82 (6) , 2434-2440
Abstract
Microband arrays improve the analytical performance and information content of electrochemical detection in flow channel relative to single-electrode configurations. However, exploiting their full advantages requires a detailed understanding of the properties of arrays, which depend on their geometry and on the hydrodynamic regimes established inside the microfluidic channel. This paper investigates the influence of two main operating situations (sequential and coupling regimes) on steady-state amperometric responses of microband arrays performing under laminar flow conditions. Simulations and experimental measurements showed that the resulting properties of the arrays are a function of the number of electrodes and average ratio between gaps and electrode widths, whether the layout of the arrays is regular or not. Since the contribution of each electrode can be finely tailored, this allows the arrays to be designed and adapted to a wide variety of experimental demands.Keywords
This publication has 39 references indexed in Scilit:
- Electrochemical Determination of Flow Velocity Profile in a Microfluidic Channel from Steady-State Currents: Numerical Approach and Optimization of Electrode LayoutAnalytical Chemistry, 2009
- Electrode array detector for microchip capillary electrophoresisThe Analyst, 2008
- General Concept of High-Performance Amperometric Detector for Microfluidic (Bio)Analytical ChipsAnalytical Chemistry, 2008
- Mesure directe in situ de la vitesse d’un écoulement microfluidique par couplage électrochimique entre deux microbandes parallèlesLa Houille Blanche, 2006
- Voltammetry under Microfluidic Control: Computer-Aided Design Development and Application of Novel Microelectrochemical ReactorsThe Journal of Physical Chemistry B, 2003
- Application of a 32-Microband Electrode Array Detection System for Liquid Chromatography AnalysisAnalytical Chemistry, 1997
- Electrochemical sensors using microarray electrodesTrAC Trends in Analytical Chemistry, 1993
- Amperometric responses of poly(chlorotrifluoroethylene)/graphite composite electrodes with varying compositions and particle sizes under flow injection and liquid chromatographic conditionsAnalytical Chemistry, 1991
- Construction and use of paired and triple band microelectrodes in solutions of low ionic strengthAnalytical Chemistry, 1988
- The behaviour of an electrochemical detector used in liquid chromatography and continuous flow voltammetryAnalytica Chimica Acta, 1978