Factors affecting masking release in cochlear-implant vocoded speech
- 1 July 2009
- journal article
- research article
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 126 (1) , 338-346
Abstract
Cochlear-implant(CI) listeners generally perform better when listening to speech in steady-state noise than in fluctuating maskers, and the reasons for that are unclear. The present study presents a new hypothesis for the observed absence of release from masking. When listening to speech in fluctuating maskers (e.g., competing talkers), CI users cannot fuse the pieces of the message over temporal gaps because they are not able to perceive reliably the acoustic landmarks introduced by obstruent consonants (e.g., stops). These landmarks are evident in spectral discontinuities associated with consonant closures and releases and are posited to aid listeners determine word/syllable boundaries. To test this hypothesis, normal-hearing (NH) listeners were presented with vocoded (6–22 channels) sentences containing clean obstruent segments, but corrupted (by steady noise or fluctuating maskers) sonorant segments (e.g., vowels). Results indicated that NH listeners performed better with fluctuating maskers than with steady noise even when speech was vocoded into six channels. This outcome suggests that having access to the acoustic landmarks provided by the obstruent consonants enables listeners to integrate effectively pieces of the message glimpsed over temporal gaps into one coherent speech stream.Keywords
This publication has 31 references indexed in Scilit:
- The contribution of obstruent consonants and acoustic landmarks to speech recognition in noiseThe Journal of the Acoustical Society of America, 2008
- Speech recognition with varying numbers and types of competing talkers by normal-hearing, cochlear-implant, and implant simulation subjectsThe Journal of the Acoustical Society of America, 2008
- Use of S-Shaped Input-Output Functions for Noise Suppression in Cochlear ImplantsEar & Hearing, 2007
- Noise Susceptibility of Cochlear Implant Users: The Role of Spectral Resolution and SmearingJournal of the Association for Research in Otolaryngology, 2005
- Restructuring speech representations using a pitch-adaptive time–frequency smoothing and an instantaneous-frequency-based F0 extraction: Possible role of a repetitive structure in soundsSpeech Communication, 1999
- Speech reception thresholds in noise with and without spectral and temporal dips for hearing-impaired and normally hearing peopleThe Journal of the Acoustical Society of America, 1998
- Effects of fluctuating noise and interfering speech on the speech-reception threshold for impaired and normal hearingThe Journal of the Acoustical Society of America, 1990
- The role of strong syllables in segmentation for lexical access.Journal of Experimental Psychology: Human Perception and Performance, 1988
- Acoustic invariance in speech production: Evidence from measurements of the spectral characteristics of stop consonantsThe Journal of the Acoustical Society of America, 1979
- Some Stages of Processing in Speech Perception1975