An optimized framework for simultaneous EEG-fMRI at 7T enabling safe, high-quality human brain imaging with millisecond temporal resolution and sub-millimeter spatial resolution
Open Access
- 4 November 2025
- journal article
- Published by MIT Press in Imaging Neuroscience
- Vol. 3
Abstract
The combination of electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) at ultra-high field (7 Tesla) offers appealing new possibilities to probe human brain function non-invasively with high coverage, millisecond temporal precision and sub-millimeter spatial precision, unraveling cortical layers and small subcortical structures. Unfortunately, this technique has remained largely inaccessible at 7T, due to prohibitive cross-modal interference effects and physical constraints. Here, we developed a first-of-its-kind EEG-fMRI acquisition framework on a clinical 7T system combining key improvements from previous research: compact EEG transmission to reduce artifact incidence, reference sensors for artifact correction, and adapted leads for compatibility with a dense radiofrequency receive array allowing state-of-the-art fMRI sensitivity and acceleration. Two implementations were tested: one using an EEG cap adapted in-house, and another using a recently designed prototype from an industrial manufacturer, intended to be further developed into a commercial device accessible to the broader community. A comprehensive evaluation in humans showed that simultaneous acquisitions, including sub-millimeter fMRI resolution, could be conducted without detectable safety issues or major practical constraints. The EEG exerted relatively mild perturbations on fMRI quality (6–11% loss in temporal SNR), without measurably affecting the detection of resting-state networks and visual responses. The artifacts induced on EEG could be corrected to a degree where the spatial, spectral, and temporal characteristics were comparable with outside recordings, and hallmark features such as resting-state alpha and eyes-closing alpha modulation could be clearly detected. Altogether, these findings indicate excellent prospects for neuroimaging applications, which can leverage the unique possibilities achievable at 7T.Keywords
Funding Information
- Swiss National Science Foundation (PZ00P2_185909)
This publication has 97 references indexed in Scilit:
- Brain state dynamics differ between eyes open and eyes closed restHuman Brain Mapping, 2024
- Data‐driven beamforming technique to attenuate ballistocardiogram artefacts in electroencephalography–functional magnetic resonance imaging without detecting cardiac pulses in electrocardiography recordingsHuman Brain Mapping, 2021
- Exploring the advantages of multiband fMRI with simultaneous EEG to investigate coupling between gamma frequency neural activity and the BOLD response in humansHuman Brain Mapping, 2018
- Epileptic networks in focal cortical dysplasia revealed using electroencephalography–functional magnetic resonance imagingAnnals of Neurology, 2011
- Simultaneous electroencephalography‐functional MRI at 3 T: An analysis of safety risks imposed by performing anatomical reference scans with the EEG equipment in placeJournal of Magnetic Resonance Imaging, 2011
- Physical modeling of pulse artefact sources in simultaneous EEG/fMRIHuman Brain Mapping, 2010
- Noise in magnitude magnetic resonance imagesConcepts in Magnetic Resonance Part A, 2008
- Metallic electrodes and leads in simultaneous EEG‐MRI: Specific absorption rate (SAR) simulation studiesBioelectromagnetics, 2004
- Physiological noise in oxygenation‐sensitive magnetic resonance imagingMagnetic Resonance in Medicine, 2001
- Investigation of the factors responsible for burns during MRIJournal of Magnetic Resonance Imaging, 2001