ECG artefact identification and removal in mHealth systems for continuous patient monitoring
Authors:
Open Access
- 15 September 2016
- journal article
- research article
- Published by Institution of Engineering and Technology (IET) in Healthcare Technology Letters
- Vol. 3 (3) , 171-176
Abstract
Continuous patient monitoring systems acquire enormous amounts of data that is either manually analysed by doctors or automatically processed using intelligent algorithms. Sections of data acquired over long period of time can be corrupted with artefacts due to patient movement, sensor placement and interference from other sources. Owing to the large volume of data these artefacts need to be automatically identified so that the analysis systems and doctors are aware of them while making medical diagnosis. Three important factors are explored that must be considered and quantified for the design and evaluation of automatic artefact identification algorithms: signal quality, interpretation quality and computational complexity. The first two are useful to determine the effectiveness of an algorithm, whereas the third is particularly vital in mHealth systems where computational resources are heavily constrained. A series of artefact identification and filtering algorithms are then presented focusing on the electrocardiography data. These algorithms are quantified using the three metrics to demonstrate how different algorithms can be evaluated and compared to select the best ones for a given wireless sensor network.Keywords
This publication has 19 references indexed in Scilit:
- Signal Quality Indices for the Electrocardiogram and Photoplethysmogram: Derivation and Applications to Wireless MonitoringIEEE Journal of Biomedical and Health Informatics, 2014
- Signal quality in cardiorespiratory monitoringPhysiological Measurement, 2012
- Signal quality indices and data fusion for determining clinical acceptability of electrocardiogramsPhysiological Measurement, 2012
- High-Bandpass Filters in Electrocardiography: Source of Error in the Interpretation of the ST SegmentISRN Cardiology, 2012
- ECG baseline wander correction by mean-median filter and discrete wavelet transform2011
- The effect of 50/60 Hz notch filter application on human and rat ECG recordingsPhysiological Measurement, 2009
- Reliable motion artifact detection for ECG monitoring systems with dry electrodes2008
- ECG quality measures in telecare monitoring2008
- A dynamical model for generating synthetic electrocardiogram signalsIEEE Transactions on Biomedical Engineering, 2003
- PhysioBank, PhysioToolkit, and PhysioNetCirculation, 2000