Comparison of Central Corneal Thickness Measurements With Optical Low-Coherence Reflectometry and Ultrasound Pachymetry and Reproducibility of Both Devices
Authors:
- Bengu E. KoktekirBKBengu E. Koktekir
- Sansal GedikSGSansal Gedik
- Berker BakbakBBBerker Bakbak
- 1 November 2012
- journal article
- research article
- Published by Wolters Kluwer Health in Cornea
- Vol. 31 (11) , 1278-1281
Abstract
To compare the accuracy of optical low-coherence reflectometry (Lenstar LS 900; Haag Streit, Köniz, Switzerland) and conventional ultrasound pachymetry (UP) (US 4000; Nidek, Japan) for measuring central corneal thickness and to assess the interexaminer reproducibilities of both devices. Department of Ophthalmology, Selcuklu Faculty of Medicine, Selcuk University was the study setting. Central corneal thickness (CCT) was measured in both eyes of 65 emmetropic patients by the same examiner using Lenstar LS 900 noncontact biometry and UP. To assess the interexaminer reproducibility, 2 different examiners consecutively obtained CCT measurements in 16 eyes with Lenstar LS 900 noncontact biometry and UP. Mean CCT measurements with Lenstar LS 900 noncontact biometry and ultrasound biometry were 541.09 ± 33.8 and 545.69 ± 34.0, respectively. Significant correlation was present between these 2 measurements; intraclass correlation coefficient was found to be 95.8% (95% confidence interval: 93.2%-97.4%)(P < 0.001). Interexaminer reproducibility with Lenstar was high, and the intraclass correlation was found to be 99.3% (95% confidence interval: 98.0%-99.7%). We have also investigated the interexaminer reproducibility with UP in these 16 patients, and the results showed a 99.2% (95% confidence interval: 97.7%-99.7%) intraclass correlation. The results of Lenstar LS 900 noncontact biometry correlated with the results of UP. It may be used as an alternative method to UP for measuring CCT. Because of the mild underestimation of CCT by Lenstar, the measurements should be carefully evaluated in patients whose intraocular pressure must strictly be monitored.Keywords
This publication has 16 references indexed in Scilit:
- Intraobserver and interobserver repeatability of ocular components measurement in cataract eyes using a new optical low coherence reflectometerGraefe's Archive for Clinical and Experimental Ophthalmology, 2010
- Central and peripheral corneal thickness measured with optical coherence tomography, Scheimpflug imaging, and ultrasound pachymetry in normal, keratoconus-suspect, and post–laser in situ keratomileusis eyesJournal of Cataract & Refractive Surgery, 2009
- Anterior Ocular Biometry Using 3-Dimensional Optical Coherence TomographyOphthalmology, 2009
- Comparison of Three Methods of Measuring Corneal Thickness and Anterior Chamber DepthAmerican Journal of Ophthalmology, 2006
- Repeatability and Reproducibility of Central Corneal Thickness Measurement With Pentacam, Orbscan, and UltrasoundOptometry and Vision Science, 2005
- Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetryJournal of Cataract & Refractive Surgery, 2005
- Corneal thickness measurement by confocal microscopy, ultrasound, and scanning slit methodsAmerican Journal of Ophthalmology, 2004
- Central corneal thickness measurements with partial coherence interferometry, ultrasound, and the Orbscan systemOphthalmology, 2004
- Specular Microscopy, Confocal Microscopy, and Ultrasound BiomicroscopyCornea, 2000
- Human Corneal Thickness and Its Impact on Intraocular Pressure MeasuresSurvey of Ophthalmology, 2000