Time‐resolved dynamic contrast‐enhanced MR urography for the evaluation of ureteral peristalsis: Initial experience
Authors:
- Sooah KimSKSooah Kim
- Ruth P. LimRLRuth P. Lim
- Vivian S. LeeVLVivian S. Lee
Open Access
- 28 October 2008
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 28 (5) , 1293-1298
Abstract
Purpose: To determine the feasibility of time‐resolved dynamic contrast‐enhanced magnetic resonance urography (MRU) for the evaluation of ureteral peristalsis using a data‐sharing 3D gradient echo sequence with spiral k‐space filling.Materials and Methods: Eight patients (M = 3, F = 5, mean 48.1 years) were referred for MRU for the evaluation for renal mass (n = 3), hematuria (n = 2), urinary tract tuberculosis (n = 1), postoperative bladder cancer (n = 1), and postoperative ureteric reimplantation (n = 1). Dynamic MRU was performed for 120 seconds at 1.5T after intravenous furosemide and gadolinium administration using an oblique sagittal, time‐resolved T1 3D gradient echo sequence with 1 second effective temporal resolution. Study quality was assessed based on artifacts and extent of ureteric visualization. Frequency of peristalsis from the renal pelvis to urinary bladder was evaluated for each subject.Results: A total of 16 ureters were examined. Image quality was good in four ureters, satisfactory in 11 ureters, and poor in one ureter. Mean peristaltic frequency was 3.5 waves per minute (range, 2.5–6.5 waves/minute) in normal ureters (n =11). Five ureters were considered abnormal (one urinary tract tuberculosis and four postsurgical ureters), and all had decreased or no peristalsis (0–1.5 waves per minute).Conclusion: MRU using a time‐resolved, data‐sharing 3D contrast‐enhanced technique is able to demonstrate ureteral peristalsis and permits quantification of ureteral peristaltic frequency. J. Magn. Reson. Imaging 2008;28:1293–1298.Keywords
This publication has 17 references indexed in Scilit:
- Computed Tomography — An Increasing Source of Radiation ExposureNew England Journal of Medicine, 2007
- Peripheral Arteries in Diabetic Patients: Standard Bolus-Chase and Time-resolved MR AngiographyRadiology, 2007
- Evaluation of Novel Technique for Studying Ureteral Function in VivoJournal of Endourology, 2007
- Feasibility of k‐t BLAST technique for measuring “seven‐dimensional” fluid flowJournal of Magnetic Resonance Imaging, 2006
- Magnetic resonance imaging as a sole method for the morphological and functional evaluation of live kidney donorsBJU International, 2005
- Renal Transit Time with MR Urography in ChildrenRadiology, 2004
- Real time high resolution magnetic resonance imaging for the assessment of gastric motility disordersGut, 2004
- Time-Resolved Three-Dimensional MR Imaging of Gastric Emptying Modified by IV Administration of ErythromycinAmerican Journal of Roentgenology, 2003
- A new approach in radionuclide imaging to ureteric peristalsis using 99Tcm-MAG 3 and condensed imagesNuclear Medicine Communications, 1991
- Cinefluorographic Studies of the Normal Upper Urinary TractRadiology, 1965