Using anatomical landmark to avoid phrenic nerve injury during balloon-based procedures in atrial fibrillation patients
- 11 July 2017
- journal article
- research article
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 39 (12) , 1369-1375
Abstract
Purpose Atrial fibrillation (AF) is an arrhythmia which affects as many as 2.7 million Americans. AF should be treated, because it can lead to a four-to-fivefold increased risk of experiencing a stroke. The American College of Cardiology/American Heart Association guidelines for the treatment of drug refractory and symptomatic paroxysmal AF denote catheter ablation as the standard of care. The newest ablation treatment, cryoballoon, uses a cold balloon tip. The biggest risk factor associated with the cryoballoon ablation is phrenic nerve injury (PNI). The purpose of this study is to measure relevant distances from specific landmarks to the right phrenic nerve (RPN) to create a safe zone for physicians. Methods Using 30 cadaveric specimens, we measured laterally from the right superior pulmonary vein orifice (RSPV) to the RPN at the level of the sixth thoracic vertebra and laterally from the lateral border of the sixth thoracic vertebral body (T6) to the RPN. The depth and width of the left atrium (LA) were also measured to establish a cross-sectional area of the LA. The cross-sectional area of the LA was then correlated with the averaged measurements to see if the area of the LA could be a predictor of the location of the RPN. Results The average distance from the RPN–RSPV was 9.6 mm (range 4.3–18.8 mm). The average RPN-T6 distance was 30.6 mm (range 13.7–49.9 mm). There was a non-significant trend that suggests as the size of the LA increases, the measured distances also increased. Conclusion Using the lateral border of the sixth thoracic vertebra as a landmark, which can be viewed under fluoroscopy during the procedure, physicians can triangulate the distance to the RSPV and determine the approximate position of the RPN. Furthermore, physicians can perform a preoperative echocardiogram to determine the size of the LA to assist in determining the position of the RPN with the hopes of avoiding injury to the RPN.Keywords
This publication has 23 references indexed in Scilit:
- Rate-Control Treatment and Mortality in Atrial FibrillationCirculation, 2015
- Incidence and characteristics of phrenic nerve palsy following pulmonary vein isolation with the second-generation as compared with the first-generation cryoballoon in 360 consecutive patientsEP Europace, 2015
- Cryoballoon Ablation of Pulmonary Veins for Paroxysmal Atrial FibrillationJACC, 2013
- Phrenic nerve palsy during ablation of atrial fibrillation using a 28-mm cryoballoon catheter: predictors and preventionJournal of Interventional Cardiac Electrophysiology, 2012
- 2012 HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial designJournal of Interventional Cardiac Electrophysiology, 2012
- Locating the right phrenic nerve by imaging the right pericardiophrenic artery with computerized tomographic angiography: Implications for balloon-based proceduresHeart Rhythm, 2010
- HRS/EHRA/ECAS Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation: Recommendations for Personnel, Policy, Procedures and Follow-UpHeart Rhythm, 2007
- Lower Incidence of Thrombus Formation With Cryoenergy Versus Radiofrequency Catheter AblationCirculation, 2003
- SURGICAL ANATOMY OF THE DIAPHRAGM AND THE PHRENIC NERVEChest Surgery Clinics of North America, 1998
- Diaphragmatic paresis: pathophysiology, clinical features, and investigation.Thorax, 1989