Monte Carlo-based diffusion tensor tractography with a geometrically corrected voxel-centre connecting method
Authors:
- N C BodammerNBN C Bodammer
- J KaufmannJKJ Kaufmann
- M KanowskiMKM Kanowski
- C TempelmannCTC Tempelmann
- 16 January 2009
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 54 (4) , 1009-1033
Abstract
Diffusion tensor tractography (DTT) allows one to explore axonal connectivity patterns in neuronal tissue by linking local predominant diffusion directions determined by diffusion tensor imaging (DTI). The majority of existing tractography approaches use continuous coordinates for calculating single trajectories through the diffusion tensor field. The tractography algorithm we propose is characterized by (1) a trajectory propagation rule that uses voxel centres as vertices and (2) orientation probabilities for the calculated steps in a trajectory that are obtained from the diffusion tensors of either two or three voxels. These voxels include the last voxel of each previous step and one or two candidate successor voxels. The precision and the accuracy of the suggested method are explored with synthetic data. Results clearly favour probabilities based on two consecutive successor voxels. Evidence is also provided that in any voxel-centre-based tractography approach, there is a need for a probability correction that takes into account the geometry of the acquisition grid. Finally, we provide examples in which the proposed fibre-tracking method is applied to the human optical radiation, the cortico-spinal tracts and to connections between Broca's and Wernicke's area to demonstrate the performance of the proposed method on measured data.Keywords
This publication has 43 references indexed in Scilit:
- Multimodal fMRI tractography in normal subjects and in clinically recovered traumatic brain injury patientsNeuroImage, 2007
- Corticospinal Tract Atrophy in Corticobasal DegenerationArchives of Neurology, 2006
- Flow-based fiber tracking with diffusion tensor and q-ball data: Validation and comparison to principal diffusion direction techniquesNeuroImage, 2005
- Eddy current correction in diffusion‐weighted imaging using pairs of images acquired with opposite diffusion gradient polarityMagnetic Resonance in Medicine, 2003
- Characterization and propagation of uncertainty in diffusion‐weighted MR imagingMagnetic Resonance in Medicine, 2003
- The basis of anisotropic water diffusion in the nervous system – a technical reviewNMR in Biomedicine, 2002
- Theoretical analysis of the effects of noise on diffusion tensor imagingMagnetic Resonance in Medicine, 2001
- In vivo fiber tractography using DT-MRI dataMagnetic Resonance in Medicine, 2000
- Microstructural and Physiological Features of Tissues Elucidated by Quantitative-Diffusion-Tensor MRIJournal of Magnetic Resonance, Series B, 1996
- MR diffusion tensor spectroscopy and imagingBiophysical Journal, 1994