Complete Atrioventricular Block after TAVI: When Is Pacemaker Implantation Safe?
- 22 April 2013
- journal article
- devices
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 36 (7) , 898-903
Abstract
Introduction Atrioventricular (AV) block is a frequent complication of transcatheter aortic valve implantation (TAVI). TAVI is routinely performed under anticoagulation using heparin, which potentially may lead to an increased bleeding rate in patients who undergo permanent pacemaker (PPM) implantation immediately after TAVI. As the number of TAVI procedures continues to rise, data on the optimal management of TAVI-related AV block are needed. Therefore, the aim of our study was to analyze PPM implantation-related complications after TAVI. Methods We retrospectively collected data on PPM implantations after TAVI in our center from January 2010 to December 2012. In total, we included 30 patients who received a PPM for TAVI-related AV block. Twelve patients (group A) underwent PPM implantation on the day of TAVI. In 18 patients (group B), PPM implantation was performed at least 1 day after TAVI (3.8 ± 4.5 days). Since all patients undergoing TAVI receive dual antiplatelet therapy (DA-therapy), we compared all implantations after TAVI with a historic patient cohort that underwent PPM implantation under DA-therapy. Results Procedure times, fluid loss via drainage systems, and drainage times were neither significantly different between groups A and B nor between all PPM implantations after TAVI compared to the historic control group. Conclusion PPM implantation immediately after TAVI is safe and can be performed without increased rate of complications.Keywords
This publication has 22 references indexed in Scilit:
- Transcatheter Aortic Valve Implantation in Patients With Severe Left Ventricular DysfunctionCirculation: Cardiovascular Interventions, 2012
- Are Elderly Patients at Increased Risk of Complications Following Pacemaker Implantation? A Meta‐Analysis of Randomized TrialsPacing and Clinical Electrophysiology, 2011
- Timing and potential mechanisms of new conduction abnormalities during the implantation of the Medtronic CoreValve System in patients with aortic stenosisEuropean Heart Journal, 2011
- No Increased Bleeding Events with Continuation of Oral Anticoagulation Therapy for Patients Undergoing Cardiac Device ProcedurePacing and Clinical Electrophysiology, 2011
- Permanent Pacemaker Insertion After CoreValve Transcatheter Aortic Valve ImplantationCirculation, 2011
- Is Antiarrhythmia Device Implantation Safe Under Dual Antiplatelet Therapy?Pacing and Clinical Electrophysiology, 2010
- The Relationship between Warfarin, Aspirin, and Clopidogrel Continuation in the Peri-procedural Period and the Incidence of Hematoma Formation after Device ImplantationPacing and Clinical Electrophysiology, 2010
- Postoperative Low‐Molecular‐Weight Heparin Bridging Is Associated with an Increase in Wound Hematoma Following Surgery for Pacemakers and Implantable DefibrillatorsPacing and Clinical Electrophysiology, 2009
- Cardiovascular Outcomes With Atrial-Based Pacing Compared With Ventricular PacingCirculation, 2006
- Early Complications After Dual Chamber Versus Single Chamber Pacemaker ImplantationPacing and Clinical Electrophysiology, 1994