CFD Simulations of Ventilation and Interunit Dispersion in Dormitory Complex: A Case Study of Epidemic Outbreak in Shanghai
Open Access
- 5 March 2023
- journal article
- research article
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 20 (5) , 4603
Abstract
Since the beginning of March 2022, a new round of COVID-19 outbreaks in Shanghai has led to a sharp increase in the number of infected people. It is important to identify possible pollutant transmission routes and predict potential infection risks for infectious diseases. Therefore, this study investigated the cross-diffusion of pollutants caused by natural ventilation, including external windows and indoor ventilation windows, under three wind directions in a densely populated building environment with the CFD method. In this study, CFD building models were developed based on an actual dormitory complex and surrounding buildings under realistic wind conditions to reproduce the airflow fields and transmission paths of pollutants. This paper adopted the Wells–Riley model to assess the risk of cross-infection. The biggest risk of infection was when a source room was located on the windward side, and the risk of infection in other rooms on the same side as the source room was large in the windward direction. When pollutants were released from room 8, north wind resulted in the highest concentration of pollutants in room 28, reaching 37.8%. This paper summarizes the transmission risks related to the indoor and outdoor environments of compact buildings.Keywords
Funding Information
- National Natural Science Foundation of China (No. 52200219, No. 21YF1430700)
- Shanghai Sailing Program (No. 52200219, No. 21YF1430700)
This publication has 45 references indexed in Scilit:
- Numerical investigation of wind-induced airflow and interunit dispersion characteristics in multistory residential buildingsIndoor Air, 2013
- Experimental investigation of outdoor and indoor mean concentrations and concentration fluctuations of pollutantsAtmospheric Environment, 2011
- The COST 732 Best Practice Guideline for CFD simulation of flows in the urban environment: a summaryInternational Journal of Environment and Pollution, 2011
- Assessment of Pollutant Dispersion in the Re-entrance Space of a High-rise Residential Building, Using Wind Tunnel SimulationsIndoor and Built Environment, 2010
- On-site quantification of re-entry ratio of ventilation exhausts in multi-family residential buildings and implicationsIndoor Air, 2007
- Multi-zone modeling of probable SARS virus transmission by airflow between flats in Block E, Amoy GardensIndoor Air, 2004
- Evidence of Airborne Transmission of the Severe Acute Respiratory Syndrome VirusNew England Journal of Medicine, 2004
- Buoyancy-driven single-sided natural ventilation in buildings with large openingsInternational Journal of Heat and Mass Transfer, 2003
- Natural ventilation in buildings: measurement in a wind tunnel and numerical simulation with large-eddy simulationJournal of Wind Engineering and Industrial Aerodynamics, 2003
- QUANTIFICATION OF UNCERTAINTY IN COMPUTATIONAL FLUID DYNAMICSAnnual Review of Fluid Mechanics, 1997