Comparison of 3D dynamic virtual model to link segment model for estimation of net L4/L5 reaction moments during lifting
- 25 February 2009
- journal article
- research article
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 12 (2) , 227-237
Abstract
The purpose of this study was to validate a 3D dynamic virtual model for lifting tasks against a validated link segment model (LSM). A face validation study was conducted by collecting x, y, z coordinate data and using them in both virtual and LSM models. An upper body virtual model was needed to calculate the 3D torques about human joints for use in simulated lifting styles and to estimate the effect of external mechanical devices on human body. Firstly, the model had to be validated to be sure it provided accurate estimates of 3D moments in comparison to a previously validated LSM. Three synchronised Fastrak™ units with nine sensors were used to record data from one male subject who completed dynamic box lifting under 27 different load conditions (box weights (3), lifting techniques (3) and rotations (3)). The external moments about three axes of L4/L5 were compared for both models. A pressure switch on the box was used to denote the start and end of the lift. An excellent agreement was found between the two models for dynamic lifting tasks, especially for larger moments in flexion and extension. This virtual model was considered valid for use in a complete simulation of the upper body skeletal system. This biomechanical virtual model of the musculoskeletal system can be used by researchers and practitioners to give a better tool to study the causes of LBP and the effect of intervention strategies, by permitting the researcher to see and control a virtual subject's motions.Keywords
This publication has 33 references indexed in Scilit:
- Calibration of position and angular data from a magnetic tracking deviceJournal of Biomechanics, 2000
- Assessment of combined movements of the lumbar spine in asymptomatic and low back pain subjects using a three-dimensional electromagnetic tracking systemManual Therapy, 1999
- Three-dimensional measurement of lumbar spine kinematics for fast bowlers in cricketClinical Biomechanics, 1998
- Evaluation of a long-range transmitter for use with a magnetic tracking device in motion analysisJournal of Biomechanics, 1998
- The Use of Surface Electromyography in BiomechanicsJournal of Applied Biomechanics, 1997
- Bending and compressive stresses acting on the lumbar spine during lifting activitiesJournal of Biomechanics, 1994
- Validation of a dynamic linked segment model to calculate joint moments in liftingClinical Biomechanics, 1992
- Identifying Patients at Risk of Becoming Disabled Because of Low-Back PainSpine, 1991
- Application of a magnetic tracking device to kinesiologic studiesJournal of Biomechanics, 1988
- A method for evaluating the biomechanical stresses resulting from manual materials handling jobsAIHA Journal, 1977