50 Hz Temporal Magnetic Field Monitoring from High-Voltage Power Lines: Sensor Design and Experimental Validation
Authors:
- Kenneth DeprezKDKenneth Deprez
- Tom Van de SteeneTSTom Van de Steene
- Leen VerloockLVLeen Verloock
- Emmeric TangheETEmmeric Tanghe
- Liesbeth GomméLGLiesbeth Gommé
- Mart VerlaekMVMart Verlaek
- Michel GoethalsMGMichel Goethals
- Karen van CampenhoutKCKaren van Campenhout
- David PletsDPDavid Plets
- Wout JosephWout Joseph
Open Access
Abstract
A low-cost, tri-axial 50 Hz magnetic field monitoring sensor was designed, calibrated and verified. The sensor was designed using off-the-shelf components and commercially available coils. It can measure 50 Hz magnetic fields originating from high-voltage power lines from 0.08 µT to 364 µT, divided into two measurement ranges. The sensor was calibrated both on-board and in-lab. The on-board calibration takes the circuit attenuation, noise and parasitic components into account. In the in-lab calibration, the output of the developed sensor is compared to the benchmark, a narrowband EHP-50. The sensor was then verified in situ under high-voltage power lines at two independent measurement locations. The measured field values during this validation were between 0.10 µT and 13.43 µT, which is in agreement with other reported measurement values under high-voltage power lines in literature. The results were compared to the benchmark, for which average deviations of 6.2% and 1.4% were found, at the two independent measurement locations. Furthermore, fields up to 113.3 µT were measured in a power distribution sub-station to ensure that both measurement ranges were verified. Our network, four active sensors in the field, had high uptimes of 96%, 82%, 81% and, 95% during a minimum 3-month interval. In total, over 6 million samples were gathered with field values that ranged from 0.08 µT to 45.48 µT. This suggests that the proposed solution can be used for this monitoring, although more extensive long-term testing with more sensors is required to confirm the uptime under multiple circumstances.Keywords
Funding Information
- The Department of Environment & Spatial Development Flanders (OMG-VPO/2021/004)
This publication has 41 references indexed in Scilit:
- Estimation of the general population and children under five years of age in France exposed to magnetic field from high or very high voltage power line using geographic information system and extrapolated field dataEnvironmental Research, 2023
- The Short‐Term Effect of Occupational Levels of 50 Hz Electromagnetic Field on Human Heart Rate VariabilityBioelectromagnetics, 2020
- Assessment of electromagnetic field levels from surrounding high-tension overhead power lines for proposed land useEnvironmental Monitoring and Assessment, 2016
- The SEMONT continuous monitoring of daily EMF exposure in an open area environmentEnvironmental Monitoring and Assessment, 2015
- The Italian national electromagnetic field monitoring networkAnnals of Telecommunications, 2008
- Non-ionizing electromagnetic radiation monitoring in GreeceAnnals of Telecommunications, 2008
- ELF‐magnetic flux densities measured in a city environment in summer and winterBioelectromagnetics, 2007
- Comparison between personal exposure to 60 Hz magnetic fields and stationary home measurements for people living near and away from a 735 kV power lineBioelectromagnetics, 1999
- Exposure of children to residential magnetic fields in Norway: Is proximity to power lines an adequate predictor of exposure?Bioelectromagnetics, 1997
- High-voltage overhead power lines in epidemiology: Patterns of time variations in current load and magnetic fieldsBioelectromagnetics, 1996