RADON AND THORON IN CAVE DWELLINGS (YANʼAN, CHINA)
Authors:
- Jens WiegandJWJens Wiegand
- Sebastian FeigeSFSebastian Feige
- Xie QuinglingXQXie Quingling
- Ulrich SchreiberUSUlrich Schreiber
- Katja WieditzKWKatja Wieditz
- Christiane WittmannCWChristiane Wittmann
- Luo XiarongLXLuo Xiarong
- 1 April 2000
- journal article
- research article
- Published by Wolters Kluwer Health in Health Physics
- Vol. 78 (4) , 438-444
Abstract
222Rn and 220Rn concentrations were measured in cave dwellings and brick houses in the region of Yan'an (China) during summer 1997. The underground dwellings are built into Quaternary loess, and all investigated houses are founded on it. The median values of indoor 222Rn and 220Rn concentrations are 42 (n = 18) and 77 Bq m−3 (n = 15) for brick houses and 92 (n = 23) and 215 (n = 17) Bq m−3 for cave dwellings. To classify the dwellings in respect to their cave-character, the fraction of walls having a direct contact to the loess is calculated for each dwelling. While the 222Rn concentrations are increasing with higher fractions, the 220Rn concentrations are not correlated with this fraction. On the other hand, due to the short half-life of 220Rn the distance from the measuring point to the walls is negatively correlated with the 220Rn concentration, while there is no correlation with the 222Rn concentration. Therefore, concentric isolines of 220Rn concentrations showing a strong gradient were detected in cave dwellings. An influence of the ventilation rate is distinct for 222Rn but weak for 220Rn. The effective dose rates for 222Rn and 220Rn and their progenies are calculated for brick houses (2.7 mSv y−1), cave dwellings (7.1 mSv y−1), and for traditional cave dwellings with a bed foundation built with loess (16.7 mSv y−1). These calculations are based on summer measurements only. It is expected that the true effective dose rates will be significantly higher. ©2000Health Physics SocietyKeywords
This publication has 4 references indexed in Scilit:
- Radon Measurements in Underground Dwellings from Two Prefectures in ChinaHealth Physics, 1996
- Thoron Exposure of Man: A Negligible Issue?Radiation Protection Dosimetry, 1994
- A Passive Measurement Technique for Characterisation of High-Risk Houses in Japan Due to Enhanced Levels of Indoor Radon and Thoron ConcentrationsRadiation Protection Dosimetry, 1992
- Long-term Measurements of 222Rn, 220Rn, 214Pb and 212Pb Concentrations in the Air of Private and Public Buildings and Their Dependence on Meteorological ParametersHealth Physics, 1975