MRI assessment of thoracic stent grafts after emergency implantation in multi trauma patients: a feasibility study
- 18 February 2011
- journal article
- chest
- Published by Springer Nature in European Radiology
- Vol. 21 (7) , 1397-1405
Abstract
To evaluate the feasibility of MRI for static and dynamic assessment of the deployment of thoracic aortic stent grafts after emergency implantation in trauma patients.Keywords
This publication has 34 references indexed in Scilit:
- Non–contrast‐enhanced MR angiography of the thoracic aorta using cardiac and navigator‐gated magnetization‐prepared three‐dimensional steady‐state free precessionJournal of Magnetic Resonance Imaging, 2008
- Expert Consensus Document on the Treatment of Descending Thoracic Aortic Disease Using Endovascular Stent-GraftsThe Annals of Thoracic Surgery, 2008
- Phase contrast MR imaging to measure changes in collateral blood flow after stenting of recurrent aortic coarctation: Initial experienceJournal of Magnetic Resonance Imaging, 2006
- Aortic Compliance Following EVAR and the Influence of Different Endografts:Determination Using Dynamic MRAJournal of Endovascular Therapy, 2006
- Endovascular management of traumatic ruptures of the thoracic aorta: A retrospective multicenter analysis of 28 cases in The NetherlandsJournal of Vascular Surgery, 2006
- Guidelines for Credentialing of Practitioners to Perform Endovascular Stent-Grafting of the Thoracic AortaThe Journal of Thoracic and Cardiovascular Surgery, 2006
- Acute traumatic aortic rupture: A comparison of surgical and stent-graft repairThe Journal of Thoracic and Cardiovascular Surgery, 2005
- 3.0 Tesla Magnetic Resonance Angiography of Endovascular Aortic Stent GraftsInvestigative Radiology, 2004
- Magnetic Resonance Imaging Versus Multislice Computed Tomography of Thoracic Aortic EndograftsJournal of Endovascular Therapy, 2002
- Artifact-Free In-Stent Lumen Visualization by Standard Magnetic Resonance Angiography Using a New Metallic Magnetic Resonance Imaging StentCirculation, 2002