Comparison of Cytopathology Yield of Fine-Needle Aspiration Biopsy Using 25G Versus 27G Needles for Melanocytic Uveal Tumors
Open Access
- 23 May 2025
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (11) , 3650
Abstract
Background/Objectives: This study aims to evaluate whether fine-needle aspiration biopsy (FNAB) of melanocytic uveal tumors (MUTs) using 27-gauge (27G) needles yields aspirates like those obtained using 25-gauge (25G) needles for cytology. Methods: A retrospective review was conducted on 32 primary uveal melanomas (PUMs). Tumors were sampled at three adjacent sites, first using a 27G needle for gene expression profile (GEP) testing, second and third with 27G and 25G needles for cytology. The endpoints evaluated were the sufficiency of aspirates for cytopathology and GEP. Results: Among the 32 patients, 17 tumors were choroidal, 6 ciliochoroidal, 7 iridociliochoroidal, and 2 exclusively iridic. Tumor diameter ranged from 3.3 mm to 23 mm (mean 13.2 mm), and thickness ranged from 0.5 mm to 12 mm (mean 6.4 mm). Aspirates from both needle sizes were sufficient for cytopathological diagnosis and GEP in 31 of 32 cases (96.9%). The single insufficient aspirate was insufficient with both the 27G and 25G needles. The cytopathology was identical in all other cases. The tumors were Class 1 in 22 cases (71.0%) and Class 2 in 9 cases (29.0%). Conclusions: FNAB aspirates of MUTs using 27G needles appear sufficient for cytology and GEP in most cases, showing a similar diagnostic yield compared to 25G needles.Keywords
All Related Versions
Funding Information
- James J. Augsburger Ocular Oncology Research & Education Fund, Department of Ophthalmology, College of Medicine, University of Cincinnati, Cincinnati, OH, USA (P30EY014801, P30 CA240139, GR004596)
- NIH Center Core (P30EY014801, P30 CA240139, GR004596)
- Prevent Blindness Unrestricted (P30EY014801, P30 CA240139, GR004596)
- Sylvester Comprehensive Cancer Center (P30EY014801, P30 CA240139, GR004596)
This publication has 15 references indexed in Scilit:
- Uveal melanoma: clinical management of ocular complications after tumor biopsyExpert Review of Ophthalmology, 2022
- Instrument Gauge and Type in Uveal Melanoma Fine Needle Biopsy: Implications for Diagnostic Yield and Molecular PrognosticationAmerican Journal of Ophthalmology, 2020
- Indications for Fine Needle Aspiration Biopsy of Posterior Segment Intraocular TumorsAmerican Journal of Ophthalmology, 2019
- Yield, Techniques, and Complications of Transvitreal and Transscleral Biopsies in Small Uveal MelanomaJAMA Ophthalmology, 2018
- Histopathologic Analysis of Transvitreal Fine Needle Aspiration Biopsy Needle Tracts for Uveal MelanomaAmerican Journal of Ophthalmology, 2017
- Fine Needle Aspiration Biopsy in Uveal Melanoma: Technique, Complications, and OutcomesAmerican Journal of Ophthalmology, 2016
- Fine-needle aspiration biopsy of uveal melanoma: outcomes and complicationsBritish Journal of Ophthalmology, 2015
- Sufficiency of FNAB aspirates of posterior uveal melanoma for cytologic versus GEP classification in 159 patients, and relative prognostic significance of these classificationsGraefe's Archive for Clinical and Experimental Ophthalmology, 2013
- Collaborative Ocular Oncology Group Report Number 1: Prospective Validation of a Multi-Gene Prognostic Assay in Uveal MelanomaOphthalmology, 2012
- Multi-Year Follow-up of Fine-Needle Aspiration Biopsy in Choroidal MelanomaOphthalmology, 2012