Performance and exergetic analysis of vapor compression refrigeration system with an internal heat exchanger using a hydrocarbon, isobutane (R600a)
Authors:
- 11 January 2008
- journal article
- research article
- Published by Hindawi Limited in International Journal of Energy Research
- Vol. 32 (9) , 824-836
Abstract
Hydrocarbons (HCs) are excellent refrigerants in many ways such as energy efficiency, critical point, solubility, transport and heat transfer properties, but they are also flammable, which causes the need for changes in standards, production and product. There are increasing number of scientists and engineers who believe that an alternative solution, which has been overlooked, may be provided by using HCs. The main objective of this study is to perform energy and exergy analyses for a vapor compression refrigeration system with an internal heat exchanger using a HC, isobutene (R600a). For a refrigeration capacity of 1 kW and cold chamber temperature of 0°C, energy and exergy balances are taken into account to determine the performance of the refrigeration system. Energy and exergy fluxes are determined, and irreversibility rates are calculated for every component of the system. It is seen that the compressor has the highest irreversibility rate, and the heat exchanger has the lowest. Also from the result of the analysis, it is found that condenser and evaporator temperatures have strong effects on energetic and exergetic performances of the system such as coefficient of performance (COP), efficiency ratio (τ), exergetic efficiency (ξ) and irreversibility rate. Copyright © 2008 John Wiley & Sons, Ltd.Keywords
This publication has 20 references indexed in Scilit:
- Performance of alternative refrigerants for residential air-conditioning applicationsApplied Energy, 2007
- Thermodynamic performance of HCFC22 alternative refrigerants for residential air-conditioning applicationsEnergy and Buildings, 2007
- Assessment of propane/commercial butane mixtures as possible alternatives to R134a in domestic refrigeratorsEnergy Conversion and Management, 2006
- Characteristics of condensing and evaporating heat transfer using hydrocarbon refrigerantsApplied Thermal Engineering, 2006
- Experimental investigation of hydrocarbon mixtures to replace HFC-134a in an automotive air conditioning systemEnergy Conversion and Management, 2006
- Experimental study of hydrocarbon mixtures to replace HFC-134a in a domestic refrigeratorEnergy Conversion and Management, 2005
- Experimental evaluation of a vapour compression plant performance using R134a, R407C and R22 as working fluidsApplied Thermal Engineering, 2004
- Experimental results for a hydraulic refrigeration system using n-butaneInternational Journal of Refrigeration, 2001
- Testing of propane/isobutane mixture in domestic refrigeratorsInternational Journal of Refrigeration, 2000
- The application of propane/butane mixture for domestic refrigeratorsApplied Thermal Engineering, 1998